30
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
All in One unit | J generation | Two-zone configuration (for 2 heating zones)
WH-ADC0309J3E5B
E
32
A
1
7
8
9
10
11
13
15
D
12
14
16
2
3
4
5
6
B
17
19
20
21
22
18
D
30
29
28
27
31
C
26
25
23 24
Front side,
Rear side
A Internal view (seen from front side)
1 Air purge valve
2 Overload protector (not visible)
3 Backup heater assembly
4 Hot water tank temperature sensor (not visible)
5 Zone 1 Water circulation pump
6 Pressure relief valve
7 Zone 2 Water filter set
8 Remote controller
9 Water pressure gauge
10 Control board cover (hinged)
11 Main PCB
12 Optional PCB
13 RCCB (for backup heater)
14 RCCB (for power supply)
15 Magnetic water filter set
16 Safety valve
B Internal detail view of upper section (seen from
right side)
17 Vortex water flow sensor
18 3-way valve
19 Zone 2 Water temperature sensor
20 Zone 2 Circulating water pump
21 Expansion vessel
22 Zone 2 Mixing valve
C Detail view of upper section (seen from rear side)
23 Zone 2 Supply water outlet (to space heating)
24 Zone 2 Return water inlet (from space heating)
25 Refrigerant gas line
26 Refrigerant liquid line
D Detail view of piping connections
27 Pressure relief valve drainage tap
28 Zone 1 Supply water outlet (to space heating)
29 Zone 1 Return water inlet (from space heating)
30 Supply water outlet (to hot water tank)
31 Fresh water inlet
E Bottom view
32 Condensate drain hole
Содержание WH-ADC0309J3E5