89
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Dimensions
PAW‑A2W‑VENTA‑L/‑R
PAW‑A2W‑VENTA‑L
PAW‑A2W‑VENTA‑R
Left side view
Front view
Front view
500
470
99
99
99
99
118
109
118
109
97
97
116
108
109
171
139
116
598
450
598
450
Ø125(x4)
Ø125(x4)
PAW‑A2W‑VENTA‑L
PAW‑A2W‑VENTA‑R
Top view
Top view
500
470
99
99
99
99
118
109
118
109
97
97
116
108
109
171
139
116
598
450
598
450
Ø125(x4)
Ø125(x4)
Unit: mm
Technical data
Heat recovery Ventilation unit
PAW-A2W-VENTA-L
PAW-A2W-VENTA-R
Supply side
Left
Right
Nominal airflow rate @ 50 Pa
m³/h
204
Maximum airflow rate @ 100 Pa
m³/h
292
Specific fan power (SFP) @ 204 m³/h
1.24
Heat exchanger rotor drive type
Variable speed
Exchanger type
Rotating
Heat recovery efficiency 1
84 %
Power supply
V / Ph / Hz
230 / 1 / 50
Power consumption
W
176
Energy Class, basic unit
A
Energy Class, unit with local control on demand
A
Noise level
dB(A)
40
Dimension (W x H x D)
mm
598 x 450 x 500
Weight
kg
46
Mounting position
Vertical