90
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Heat recovery Ventilation unit
PAW-A2W-VENTA-L
PAW-A2W-VENTA-R
Duct connections
mm
DN125
Filter class, supply air
F7/ePM1 60 %
Filter class, exhaust air
M5/ePM10 50 %
Minimum outdoor temperature
°C
-20
1) Heat recovery efficiency according to EN 13141-7.
Note:
Heat recovery Ventilation unit is produced by Systemair.
4.8.5 Recommended on-site accessories
Panasonic recommends the following on-site accessories It is particularly advisable to use building
components and accessories recommended by the manufacturer. Use the correct interfaces
4.7.2 External interfaces (inputs/outputs), p. 65
) and connection conditions when connecting
the accessories.
Overview of the specifications of the recommended on-site accessories
Construction / Indoor unit type
Bi‑bloc systems
Mono‑
bloc
systems
with All in One
unit
with
hydrokit
Device generation
J / H
F
J / H
G
J / H
Model type (configuration)
–
B
C
No.
Component
Quan‑
tity
Description
Model
Power
supply
Make
A
2-way valve set
1
Electrical motor actuator SFA21/18
230 V AC
Siemens
●
2
●
2
●
2
●
2
●
2
●
2
●
2
2-way valve
VVI46/25
–
B
3-way valve set
2
Electrical motor actuator SFA21/18
230 V AC
Siemens
●
●
●
●
●
●
●
3-way valve
VXI46/25
–
C
Room thermostat
1
Analogue
RAA20
230 V AC
Siemens
●
●
●
●
●
●
●
Programmable
REV200
D
Room thermostat
1
Wired
PAW-A2W-RTWIRED
230 V AC
1
●
●
●
●
●
●
●
Wireless
PAW-A2W-RTWIRELESS 230 V AC
1
E
Mixing valve
1
–
167032
230 V AC
Caleffi
●
³
●
●
●
●
●
F
Pump
1
–
Yonos 25/6
230 V AC
Wilo
●
³
●
●
●
G
Temperature sensor for buffer tank
1
–
PAW-A2W-TSBU
–
1
●
³
●
●
●
H
Outdoor temperature sensor
1
–
PAW-A2W-TSOD
–
1
●
³
●
●
●
I
Inflow temperature sensor for
heating circuit
1
–
PAW-A2W-TSHC
–
1
●
³
●
●
●
J
Room temperature sensor
1
–
PAW-A2W-TSRT
–
1
●
³
●
●
●
K
Solar sensor
1
–
PAW-A2W-TSSO
–
1
●
³
●
●
●
L
Base pan heater for outdoor/
mono-bloc units
1
Only for models with
3 or 5 kW
CZ-NE2P
Panasonic
●
●
●
●
●
M
Base pan heater for outdoor/
mono-bloc units
1
For all models after
the F generation with
> 5 kW
CZ-NE3P
Panasonic
●
●
●
●
●
●
●
N
Additional PCB for expanded
controller functionality
1
–
CZ-NS4P
Panasonic
●
³
●
●
●
O
Interface for the control over the
Internet via Aquarea Smart Cloud
1
–
CZ-TAW1
Panasonic
●
●
●
●
●
P
10 m extension cable for
CZ-TAW1
CZ-TAW1-CBL
Panasonic
●
1 To be sourced through Panasonic
2 Only for unlocked cooling mode
3 Already installed at the time of dispatch
We recommend that the client-provided accessories be sourced from the manufacturers named in the table.