6-7
6-6
6. Test run
Wired remote
cont
ro
ller displ
ay
Cause
Correction
Nothing
is
displ
ay
ed
Nothing is displ
ay
ed
E 0
1
dis
pl
ay
ed
E 0
2
displ
ay
ed
E 0
9
displ
ay
ed
E 1
4
displa
ye
d
E 0
4
displa
ye
d
E 0
6
di
spla
ye
d
E 1
5
displa
ye
d
E 1
6
displa
ye
d
E 2
0
di
spla
ye
d
P 0
5
di
spla
ye
d
L 0
2
displa
ye
d
L 1 3
displ
ay
ed
P 0
9
displa
ye
d
L 0
7
displa
ye
d
Indoor unit receiver lamp
Operating
lamp
is b
linking.
Standb
y lamp
is
b
linking.
Both the Operatio
n
lamp and
S
ta
ndb
y
lamp are b
linking
togethe
r.
Operation lamp an
d
S
ta
ndb
y lamp are
blinking alter
natel
y.
Timer lamp an
d
S
ta
ndb
y lamp are
blinking alter
natel
y.
Remote co
ntroller is
not connected correctly
.
Indoor
un
it po
wer
is
not ON.
A
utomatic address
setti
ng has
not been
completed. Inter-unit control wir
ing is cut or is
not
connected correctly
.
Remote controller is
not conn
ected correctly
(remote controller receiving
fa
ilure).
Remote co
ntroller is
not connected correctly
(failure in transmission from remote controlle
r
to indoor
unit).
Indoor-outdoor inter-unit wi
ring is
no
t
connected correctly
.
Indoor
unit capacity is too lo
w.
Indoo
ru
nit capacity
is too hi
gh.
No
ser
ial sign
al is
bei
ng receiv
ed at all from
the indoor
units
.
Inter-unit circ
uit or ope
n phase
in
the
ou
tdoor
unit po
we
r
Insu
fficie
nt
gas
Indoor-outdoor
unit type mismatch
The indoor
unit ceiling panel connector is
not
conn
ected correctly
.
Remote controller is
not connected with
indoor
unit correctly
Indoor
unit po
wer is
not ON.
A
utomatic address
setting has
not been
completed. Inter-unit control wir
ing is cut or is
no
t
connected correctly
.
Remote controller is
not connected with
indoor
unit correctly
Remote controller is
not connected with
indoor
unit correctly
Same as at left
Indoor-outdoor inter-u
nit wir
ing is cut or
is
not connected correctly
.
Same as
at left
Re
ve
rsed phase or open phase in the
3-phase po
wer at one of the outdoor
un
its in the
gr
ou
p
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same as at left
Same
as at left
Same as at left
Same as
at left
S
ame as at left
Same as at left
Same as at left
Same as at left
Same
as
at left
Remote controller cross
ov
er wir
ing is cut or
is
not connected correctly
.
Indoor
unit ceiling panel connector is
not
connected correctly
.
Remote controller crosso
ve
r wir
ing is co
nn
ected
to the indoor
unit, ho
we
ve
r it is
set
fo
r individual
operation.
Connect the remote controller correctl
y.
Tu
rn
ON the indoor
unit po
we
r.
2 remote controllers are set as the main remote
controlle
r.
Chec
k the remote controller and inter-unit
control wir
ing.
Perf
or
m automatic address
setting.
Connect the remote controller correctly
.
Ref
er to 11-8-6 Main-sub remote control, and
mak
e the correct settings
.
Chec
k the remote controller crosso
ve
r wir
ing.
Perf
or
m automatic address
setting again.
Connect the wir
ing correctly
.
Re
fe
r to 11-
8S
ystem Control, and ma
ke
the
correct
settings
.
Chec
k that the total capacitie
s of the
in
door
and outdoor
un
its are approp
riat
e.
Che
ck
that the indoor
unit po
wer is ON, and that
the inter-unit control wir
ing is connected correctly
.
Re
ve
rse 2 phases of the outdoor
uni
t3
-phase
po
wer and connect them correctly
.
Chec
k that the indoor and
ou
tdoor
unit type
s
are correct
.
Perf
or
m automatic address
setti
ng.
Connect the indoor
unit ceiling panel
co
nn
ector correctly
.
Ceiling panel connector at one of the indoor
unit
s in the
gro
up
is
not
connected correctly
.
Re
ve
rsed phase or ope
n phase in the
outdoor
uni
t3
-phase po
we
r
1:1 connectio
no
gni
s(
r
G
)e
pyt
en
oit
ce
nn
oc
pu
l
Simultaneous-operation multi
system
(fle
xib
le combination)
Control
by
main-sub
remote controllers
6-7.
Ta
ble of Self-Diagnostic Functions and Corrections (X,
T,
U,
K
Type)
6-7. Table of Self-Diagnostic Functions and Corrections (Type F2, U2, T2, K2, U1, K1, T1 and F1)
6
SM830203-04.indb 6
15/10/14 16:25:09
Содержание U-26PE1U6
Страница 8: ...vii MEMO...
Страница 76: ...1 68 1 Specifications 1 4 Dimensional Data Outdoor Unit U 26PE1U6 U 26PS1U6 U 36PE1U6 U 36PS1U6 1...
Страница 77: ...1 69 1 Specifications 1 4 Dimensional Data Outdoor Unit U 42PE1U6 U 42PS1U6 1...
Страница 218: ...2 12 MEMO...
Страница 219: ...3 1 3 2 Indoor Units 3 2 Outdoor Units 3 14 3 ELECTRICAL DATA 3 1 3...
Страница 220: ...3 2 3 Electrical data 3 1 Indoor Units Concealed Duct Type S 26PF2U6 S 36PF2U6 3...
Страница 221: ...3 3 3 Electrical data 4 Way Cassette Type S 26PU1U6 S 36PU1U6 S 42PU1U6 3...
Страница 222: ...3 4 3 Electrical data 4 Way Cassette Type S 26PU1U6 S 36PU1U6 S 42PU1U6 3...
Страница 223: ...3 5 3 Electrical data Wall Mounted Type S 26PK1U6 3...
Страница 224: ...3 6 3 Electrical data Wall Mounted Type S 26PK1U6 3...
Страница 225: ...3 7 3 Electrical data Ceiling Type S 26PT1U6 S 36PT1U6 S 42PT1U6 3...
Страница 226: ...3 8 3 Electrical data Ceiling Type S 26PT1U6 S 36PT1U6 S 42PT1U6 3...
Страница 227: ...3 9 3 Electrical data Low Silhouette Ducted Type S 26PF1U6 S 36PF1U6 3...
Страница 228: ...3 10 3 Electrical data Low Silhouette Ducted Type S 26PF1U6 S 36PF1U6 3...
Страница 230: ...3 12 3 Electrical data Wall Mounted Type S 26PK2U6 3...
Страница 232: ...3 14 3 Electrical data 3 2 Outdoor Units U 26PE1U6 3...
Страница 233: ...3 15 3 Electrical data U 26PE1U6 3...
Страница 234: ...3 16 3 Electrical data U 26PS1U6 3...
Страница 235: ...3 17 3 Electrical data U 26PS1U6 3...
Страница 236: ...3 18 3 Electrical data U 36PE1U6 3...
Страница 237: ...3 19 3 Electrical data U 36PE1U6 3...
Страница 238: ...3 20 3 Electrical data U 36PS1U6 3...
Страница 239: ...3 21 3 Electrical data U 36PS1U6 3...