EN50
Specifi cations
Rating
220-240 V ~ , 50 Hz, 0.8 A
Power consumption
Approx. 130 W (approx. 1 W during standby)
Main unit
Dimensions
Approx. 200(W) × 123(D) × 318(H) mm
Weight
Approx. 4.1 k
g
(approx. 4.6 k
g
when full of water)
Temperature of water used by Alkaline Ionizer Under 35 °C (under 80 °C for bypass selector)
Pressure of water used by Alkaline Ionizer
(dynamic pressure)
70 kPa to 350 kPa
Usable water service pressure
(static pressure)
70 kPa to 750 kPa
Electrolysis
Electrolysis method
Continuous electrolysis
Output water volume
(fl ow of water produced)
2.0 L/min. (at 100 kPa water pressure)
3.0 L/min. (at 200 kPa water pressure)
Electrolysis capability
selection
Alkaline: 4 levels; weak acidic: 2 levels
Continuous operation
capability
Approx. 30 minutes at room temperature (approx. 10 minutes
for Stronger at Alkaline 3 (Drinking water in daily life), Alkaline
4 capability (Strongly Alkaline), Weak Acidic)
(Note 2)
Electrolyzer life
Approx. 850 hours cumulative (ion water production time,
cleaning time only)
Electrolytic cleaning
Auto cleaning method (cleaning time: approx. 35 seconds,
waste water drain time: approx. 15 seconds)
Purifi ed water output volume
2.5 L/min. (at 100 kPa water pressure)
Filtration fl ow volume
2.5 L/min. (at 100 kPa water pressure)
Cartridge Installed In the unit
TK-AS45C1-EX
Purifi cation
capacity
(Note 1)
Free residual chlorine
12 000 L
(Note 3)
Turbidity
12 000 L
(Note 4)
Total trihalomethane
12 000 L
(Note 3)
Chloroform
12 000 L
(Note 3)
Bromodichloromethane
12 000 L
(Note 3)
Dibromochloromethane
12 000 L
(Note 3)
Bromoform
12 000 L
(Note 3)
Tetrachloroethylene
12 000 L
(Note 3)
Trichloroethylene
12 000 L
(Note 3)
1,1,1-Trichloroethane
12 000 L
(Note 3)
CAT
12 000 L
(Note 3)
2-MIB (mold smell)
12 000 L
(Note 3)
Soluble lead
12 000 L
(Note 3)
Substances
other than
above that can
be removed
Iron (particulate form)
Can be removed
(Note 5)
Aluminium (neutral)
Can be removed
(Note 5)
Geosmin (mold smell)
12 000 L
(Note 5)
Phenols
12 000 L
(Note 5)
Guide for time to replace cartridge
Approx. 1 year
(Note 6)
Filter material
Non-woven fabric, granular activated carbon, ceramic,
powdered activated carbon, hollow fi ber membrane
Components which cannot be fi ltered out
Iron dissolved in water, heavy metals (silver, copper, etc.), salt
(seawater)
Length of power cord
Approx. 3 m
Power protection device
Current fuse: 2.5 A
Overheating protection devices
(inside isolation transformer)
Overheating protector (automatic resetting type, activated at
temperature of 120 °C)
Thermal fuse (activated at temperature of 145 °C) × 1
TK-AS66-ZEX̲En.indb 50
TK-AS66-ZEX̲En.indb 50
2017/01/30 15:04:26
2017/01/30 15:04:26