Symptom
Check following point
Reference
page
Oth
er
Very little or no water
is discharged from the
Alkaline Ionizer
“Flow reduced”,
“Too much
tightened at the
faucet?” or “Bent
hose?” displays
appear alternately.
Has the fl ow at the faucet been reduced too much?
Open up the faucet.
EN29
Is the water pressure too low?
Open up the faucet all the way and increase the water fl ow
at the main water supply.
Is the fi lter of the bypass selector clogged?
If it is, clean the fi lter.
EN34
Has the cartridge been installed properly?
EN37
~
EN38
Has the water supply been cut off ?
EN40
Is the water supply hose bent or fl attened?
EN13
~
EN15
If the display appears again even after taking the above action,
the fl ow has diminished because of a clogged cartridge or other
such reason. Replace the cartridge.
–
Much water comes out
The water amount from the main spout varies depending on
the kind of water and/or selection of the water quality even
though the amount of source water stays constant.
–
“Reduce fl ow” has
become more likely to
be displayed
Maximum fl ow varies depending on the kind of water and/or
selection of the water quality.
The water comes out
from the main spout is
warm.
When water starts to run through the Alkaline Ionizer, water
which was kept at room temperature while no water was
fl owing to the Alkaline Ionizer or water warmed by the heat
inside the Alkaline Ionizer may come out.
Allow the water to keep fl owing for about 0.6 liter (about
15 seconds) before uses.
–
The buzzer does not
sound even when
using the “Weak
Acidic” setting
Has “OFF” been set for the “Weak acidic buzzer” setting?
EN31
The water produced by
the Alkaline Ionizer has
an odor or unpleasant
taste or is turbid
The ability of the cartridge to remove odors, unpleasant tastes
and turbidity has deteriorated.
Replace the cartridge.
EN37
~
EN38
The pH level of the
water produced by the
Alkaline Ionizer is not
within the rough pH
level range
The pH level may be a little high when a new cartridge is used
(for the fi rst week or so).
(This is not a malfunction. Measure the pH level again after a
week.)
–
The pH level of weak
acidic water is neutral
If the pH level of weak acidic water is 6.5 or so, it may not be
possible to distinguish it from the pH 7 level (neutral) in the pH Chart.
Test the water coming out of the drain outlet while using the
“Weak Acidic” setting, and if it is 10 to 11, it means that the
pH level for weak acidic water is 6.5 or so.
–