177
Available commands are listed below.
N Show the next page.
Press "N." The screen shows the next port.
P Show the previous page.
Press "P." The screen shows the previous port.
S Enable/disable a sending SNMP trap.
Press "S." The command prompt changes to " Enable or Disable Limit trap(E/D)>."
Press "E" to enable the sending SNMP trap. Press "D" to disable it.
R Configure the Rx power threshold settings.
Press "R." The command prompt changes to " Auto or Manual (A/M)>." Press "A" to
set the SFP default value. Press "M" to set the value manually. If "M" is selected, the
command prompt changes to " High or Low(H/L)>." Press "H" to set the high alarm
or warning value. Press "L" to set the low alarm or warning value. Upon setting, the
command prompt changes to " Alarm or Warning(A/W)>." Select "A" for alarm.
Select "W" for warning. Then, the command prompt changes to " Enter value>."
Enter the threshold value.
T Configure the Tx power threshold settings.
Press "T." The command prompt changes to " Auto or Manual (A/M)>." Press "A" to
set the SFP default value. Press "M" to set the value manually. If "M" is selected, the
command prompt changes to " High or Low(H/L)>." Press "H" to set the high alarm
or warning value. Press "L" to set the low alarm or warning value. Upon setting, the
command prompt changes to " Alarm or Warning(A/W)>." Select "A" for alarm.
Select "W" for warning. Then, the command prompt changes to " Enter value>."
Enter the threshold value.
V Configure the Voltage threshold settings.
Press "V." The command prompt changes to " Auto or Manual (A/M)>." Press "A" to
set the SFP default value. Press "M" to set the value manually. If "M" is selected, the
command prompt changes to " High or Low(H/L)>." Press "H" to set the high alarm
or warning value. Press "L" to set the low alarm or warning value. Upon setting, the
command prompt changes to " Alarm or Warning(A/W)>." Select "A" for alarm.
Select "W" for warning. Then, the command prompt changes to " Enter value>."
Enter the threshold value.
E Configure the Temparature threshold settings.
Press "E." The command prompt changes to " Auto or Manual (A/M)>." Press "A" to
set the SFP default value. Press "M" to set the value manually. If "M" is selected, the
command prompt changes to " High or Low(H/L)>." Press "H" to set the high alarm
or warning value. Press "L" to set the low alarm or warning value. Upon setting, the
command prompt changes to " Alarm or Warning(A/W)>." Select "A" for alarm.
Select "W" for warning. Then, the command prompt changes to " Enter value>."
Enter the threshold value.
B Configure the bias current threshold settings.
Press "B." The command prompt changes to " Auto or Manual (A/M)>." Press "A" to
set the SFP default value. Press "M" to set the value manually. If "M" is selected, the
command prompt changes to " High or Low(H/L)>." Press "H" to set the high alarm
or warning value. Press "L" to set the low alarm or warning value. Upon setting, the
command prompt changes to " Alarm or Warning(A/W)>." Select "A" for alarm.
Select "W" for warning. Then, the command prompt changes to " Enter value>."
Enter the threshold value.
Q Return to the previous menu.