Chapter 4
Settings — [DISPLAY OPTION] menu
ENGLISH - 119
Setting [STARTUP]
Automatically enable/disable the shutter function (shutter: closed/opened) when the power is turned on.
1) Press
as
to select [SHUTTER SETTING].
2) Press the <ENTER> button.
f
The
[SHUTTER SETTING]
screen is displayed.
3) Press
as
to select [STARTUP].
4) Press
qw
to switch the item.
[OPEN]
The projector goes into projection mode with the shutter function disabled (shutter: opened) when the
power is turned on.
[CLOSE]
The projector goes into projection mode with the shutter function enabled (shutter: closed) when the
power is turned on.
Note
f
If this item is set to [CLOSE] while the [PROJECTOR SETUP] menu
→
[LENS]
→
[ACTIVE FOCUS OPTIMIZER]
→
[ACTIVE FOCUS] is
set to [ON], the temperature detection correction of the active focus optimizer function will not operate when the projector is turned on next
time.
The operation of the temperature detection correction of the active focus optimizer function will start when one of the following operations is
performed.
g
Pressing the <SHUTTER> button on the remote control or the control panel to disable the shutter function (shutter: opened)
g
Switching the setting in the [DISPLAY OPTION] menu
→
[SHUTTER SETTING]
→
[STARTUP] from [CLOSE] to [OPEN]
Setting the shutter synchronization function
The shutter synchronization function is a function to synchronize the shutter operation of the specified projector
to other projectors, and the effect using the shutter function including the fade out/fade in operation can be
synchronized.
To use the shutter synchronization function, it is necessary to connect the projectors targeted for synchronization
in a loop with daisy chain connection using the <SERIAL/MULTI PROJECTOR SYNC IN> terminal and the
<SERIAL/MULTI PROJECTOR SYNC OUT> terminal. For details of how to connect the projectors, refer to
“Connecting example when using the contrast synchronization function/shutter synchronization function”
(
x
page 50).
1) Press
as
to select [SHUTTER SETTING].
2) Press the <ENTER> button.
f
The
[SHUTTER SETTING]
screen is displayed.
3) Press
as
to select [MULTI PROJECTOR SYNC].
4) Press the <ENTER> button.
f
The
[MULTI PROJECTOR SYNC]
screen is displayed.
5) Press
as
to select [MODE].
6) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Select this item when the contrast synchronization function and the shutter synchronization function
are not used.
[MAIN]
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item only on one projector that becomes the synchronization source of the shutter operation
within the linked projectors.
[SUB]
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item in all the linked projectors excluding the projector set as the [MAIN].
f
When anything other than [OFF] is selected, the diagnostic result is displayed in [LINK STATUS], indicating
if all the projectors including the projectors targeted for synchronization are correctly connected, and if
[MODE] is correctly set.
Содержание PT-MZ13K
Страница 52: ...52 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with...
Страница 162: ...162 ENGLISH Chapter 5 Operations This chapter describes how to use each function...
Страница 217: ...ENGLISH 217 Chapter 7 Appendix This chapter describes specifications and after sales service for the projector...
Страница 245: ...Index ENGLISH 245 Web control 166 Z ZOOM 89 ZOOM button Remote control 27 67...