50
UF-9000
JUN 2004
Ver. 2.0
DP-180/190
Note:
These error codes will appear only when the optional accessories are installed.
E4- 10 Exhaust Fan Motor Rotation
(Fuser Unit Side)
1. Exhaust Fan connector is disconnected.
2. Exhaust Fan is defective.
3. LVPS connector is disconnected.
4. LVPS is defective.
5. Engine PCB is defective.
E5: System Error
Code
Function
Check Points
E5- 05 SPC Firmware Failure
1. SPC PCB is defective.
E5- 11 Thermistor, Toner Sensor
1. SC/Engine PCB connector is disconnected.
2. SC/Engine PCB is defective.
E5- 12 Main CPU/SPC Interface Error
1. SC/SPC PCB connector is disconnected.
2. SC/SPC PCB is defective.
E7: Optional Unit Error
Code
Function
Check Points
E7- 90 Hardware Key Error
Incorrect Hardware Key is installed.
E13: Low Toner or Out of Toner
Code
Function
Check Points
E13
TONER IS RUNNING LOW
or
OUT OF TONER
1. Toner Cartridge is incorrectly installed.
2. Out of Toner.
3. Low Toner Sensor is disconnected.
4. Low Toner Sensor is defective.
5. Engine PCB connector is disconnected.
6. Engine PCB is defective.
E4: Fuser Unit Error
Code
Function
Check Points
Содержание Panafax UF-9000
Страница 31: ...31 UF 9000 JUN 2004 Ver 2 0 DP 180 190 2 3 Preventive Maintenance Points...
Страница 47: ...47 UF 9000 JUN 2004 Ver 2 0 DP 180 190 Sensor and Switch Location...
Страница 115: ...115 JUN 2004 Ver 2 0 UF 9000 DP 180 190 A C D E B 8 1 3 4 5 6 7 2 2 2 Fig 3 CCD 306 303 W8 W8 301 305 305 1922...
Страница 187: ...187 UF 9000 JUN 2004 Ver 2 0 DP 180 190 memo...
Страница 188: ...E...