Preventive Maintenance Check List
The chart outlined below is a general guideline for maintenance. The list is for an average usage of 50
transmitted and received documents per day. Needless to say, the environmental conditions and actual use
will vary these factors. The chart below is for reference only.
Note:
1. Wet Cloth represents a soft cloth saturated with water. For stubborn toner accumulation, wipe with a
soft cloth saturated with Isopropyl Alcohol first, then follow up with a soft cloth saturated with water.
2. The Maintenance Cycle is based on the Counter Information for each individual module.
To verify the counter information, print the Total Counter List using the Service Mode: F7 - Electronic
Counter - 00 (List Print).
3. Cleaning, Replacement and Adjustment Cycle (Sheet) are based on using Panasonic's recommended
standard paper and supplies. These cycles may vary with the kind of paper used, Paper size,
orientation, print duty, continuous/interval print and/or ambient conditions.
•
Total Counter View Mode on the LCD
The Total Counter can be displayed on the Panel Display by pressing "COPY SIZE" and "PAPER TRAY"
keys simultaneously in Standby mode for quick reference.
•
LCD Contrast
Adjustment
Press holding the “CLEAR” key and press “ORIGINAL SIZE” key for Lighter or “COPY SIZE” key for
Darker.
No.
Preventive
Maintenance
Parts
Ref.
No.
Cleaning
Replacement/Adjustment
Ref.
Counter
Cycle
(Sheet)
Method
Cycle
(Sheet)
Procedure
ADF Unit
1 Separation Rubber
547
10K
Wet soft cloth
50K
Refer to
2.2.1. of the
Service
Manual
F7-08
2 Pickup Roller
414
10K
Wet soft cloth
100K
3 ADF Roller
417
10K
Wet soft cloth
100K
4 Feed Roller
516
10K
Wet soft cloth
100K
Paper Feed Module
5 Pickup Roller
1316
10K
Wet soft cloth
85K
Refer to
2.2.9. of the
Service
Manual
F7-12
6 Separator Pad
1615
10K
Wet soft cloth
85K
7 Bias Transfer Roller
(BTR)
1503
10K
Dry soft cloth
85K
Refer to
2.2.10. of the
Service
Manual
2nd Paper Feed Module
8 Pickup Roller
1733
10K
Wet soft cloth
85K
Refer to
2.2.12. of the
Service
Manual
F7-13
9 Separator Pad
1812
10K
Wet soft cloth
85K
Fuser Unit
10 Fuser Unit
1117
-
-
85K
Refer to
2.2.8. of the
Service
Manual
F7-02
TOTAL COUNTER
1234
Содержание Panafax UF-9000
Страница 31: ...31 UF 9000 JUN 2004 Ver 2 0 DP 180 190 2 3 Preventive Maintenance Points...
Страница 47: ...47 UF 9000 JUN 2004 Ver 2 0 DP 180 190 Sensor and Switch Location...
Страница 115: ...115 JUN 2004 Ver 2 0 UF 9000 DP 180 190 A C D E B 8 1 3 4 5 6 7 2 2 2 Fig 3 CCD 306 303 W8 W8 301 305 305 1922...
Страница 187: ...187 UF 9000 JUN 2004 Ver 2 0 DP 180 190 memo...
Страница 188: ...E...