43
UF-9000
JUN 2004
Ver. 2.0
DP-180/190
2.6.3.
LSU Image Side to Side Adjustment for the ADU
1. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
2. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
3. Perform the Service Mode F1-06 (Print Test Pattern 4).
4. Check the gap of the print pattern from the paper edge, refer to the Figure above.
5. Perform the Service Mode F6-16 (ADU Side Adjust), to adjust the gap to be 5 mm.
6. If the gap is less than 5 mm, input a (+) value. If more than 5 mm, input a (-) value.
7. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
2.6.4.
Original Registration & CCD Read Adjustments
1. Place the Original Document on the Platen Scanner.
2. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
3. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
4. Perform the Service Mode F2 (Single Copy Test).
5. Check the Image size of the Copy and the Original as Portrait.
6. Perform the Service Mode F6-03 (Original Registration), to adjust the Original Registration.
7. If the gap is smaller than the Original, input a (-) value. If bigger than the Original, input a (+) value.
8. Perform the Service Mode F6-53 (CCD Read Position), to adjust the CCD Read for the side
position.
9. If the gap is smaller than the Original, input a (+) value. If bigger than the Original, input a (-) value.
10. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
2.6.5.
ADF Original Read Edge & ADF Main Scan Adjustments
1. Place the Original Document on the ADF.
2. Insert Letter or A4 size paper into the 1st tray and change the tray setting to the appropriate paper
size. Empty all the remaining trays (including the bypass tray) to disable them.
3. Press “
FUNCTION
”, “
ORIGINAL SIZE
” keys and then Key “
3
” on the keypad sequentially.
4. Perform the Service Mode F2 (Single Copy Test).
5. Check the Image size of the Copy and the Original as Portrait.
6. Perform the Service Mode F6-91 (Original Read Edge ADF), to adjust the ADF Original Read Edge.
7. If the gap is less than the Original, input a (+) value. If bigger than the Original, input a (-) value.
8. Perform the Service Mode F6-90 (ADF Image Read Start), to adjust the ADF Main Scan for Side
position.
9. If the gap is less than the Original, input a (+) value. If bigger than the Original, input a (-) value.
10. Press "
STOP
" first and then press "
FUNCTION
" + "
CLEAR
" keys simultaneously to return to
standby.
Содержание Panafax UF-9000
Страница 31: ...31 UF 9000 JUN 2004 Ver 2 0 DP 180 190 2 3 Preventive Maintenance Points...
Страница 47: ...47 UF 9000 JUN 2004 Ver 2 0 DP 180 190 Sensor and Switch Location...
Страница 115: ...115 JUN 2004 Ver 2 0 UF 9000 DP 180 190 A C D E B 8 1 3 4 5 6 7 2 2 2 Fig 3 CCD 306 303 W8 W8 301 305 305 1922...
Страница 187: ...187 UF 9000 JUN 2004 Ver 2 0 DP 180 190 memo...
Страница 188: ...E...