74
UF-9000
JUN 2004
Ver. 2.0
DP-180/190
F9
Unit
Maintenance
06
RAM
Initialize
00 Parameter Initialize
Resets the Fax and Function
parameters to default values.
01 All Job Clear
Clears all Jobs stored in Flash Memory.
02 LBP Error Log Clear Clears LBP Error log
03 Shipment Set
Clears All Jobs, All Preset Data,
Parameter Initialize & Resets the
Counters (Fax).
04 LBP Fuser Reset
Clears the LBP fuser error.
05 Dept. Counter Clear
07 Firmware
Update
00 Update FROM Card Updates the firmware in the machine
with the Master Firmware Card.
01 Update from USB
Updates the firmware in the machine
with the USB.
08 Program
Backup
(Refer to
Sect. 2.5.
of the
Service
Manual)
00 Main
Onboard F-ROM 4MB
01 Option 1 all
Slot 1 FRM8 PCB 8MB
02 Option 1 a
Slot 1 FRM8 PCB 4MB (a)
03 Option 1 b
Slot 1 FRM8 PCB 4MB (b)
04 Not Used
Slot 2 FRM8 PCB 8MB
05 Not Used
Slot 2 FRM8 PCB 4MB (a)
06 Not Used
Slot 2 FRM8 PCB 4MB (b)
09 Update Prog. Card
Creates a Master Firmware Card using
the Firmware Update Kit. A 4MB or 8MB
Flash Memory Card will be required
depending upon the model.
10 Program
Copy
00 From card to slot 1
Configuration for Program copy.
01 From card to slot 2
02 From slot 1 to card
03 From slot 1 to slot 2
04 From slot 2 to card
05 From slot 2 to slot 1
11 Parameter Backup
Backup the Parameter.
12 Parameter Restore
Restore the Parameter.
13 Page Memory Size
Displays the page memory size (MB).
14 Sort Memory Size
Displays the sort memory size (MB).
F9 Mode
Service
Mode
Item
Remarks
Содержание Panafax UF-9000
Страница 31: ...31 UF 9000 JUN 2004 Ver 2 0 DP 180 190 2 3 Preventive Maintenance Points...
Страница 47: ...47 UF 9000 JUN 2004 Ver 2 0 DP 180 190 Sensor and Switch Location...
Страница 115: ...115 JUN 2004 Ver 2 0 UF 9000 DP 180 190 A C D E B 8 1 3 4 5 6 7 2 2 2 Fig 3 CCD 306 303 W8 W8 301 305 305 1922...
Страница 187: ...187 UF 9000 JUN 2004 Ver 2 0 DP 180 190 memo...
Страница 188: ...E...