151
Maintenance and Inspections: Maintenance
Mai
n
ten
ance an
d Insp
ecti
o
n
s
LENS
1
RET-SW
ON/OFF of the return video
RETURN ON: GND
RETURN OFF: OPEN
2
REC-START/STOP
Control for recording start/stop
3
GND
GND
4
IRIS-AUTO
ON/OFF of the forced iris servo
SERVO ON: 5V
±
0.5V
SERVO OFF: OPEN
5
IRIS-CONT
Control output for the lens iris
F2.8: –6.2 V, F16: 3.4 V, CLOSE: 2.5 V
6
UNREG-12V
+12V power supply for the lens (Max. 1.5 A)
7
IRIS-POSI
Iris position signals
3.4 V (F16) to 6.2 V (F2.8)
8
IRIS-G-MAX
IRIS REMOTE/LOCAL (AUTO) signals
REMOTE:
5V
±
0.5V
LOCAL (AUTO): GND
9
EXT-POSI
ON/OFF of the built-in extender
EXTENDER ON: GND
EXTENDER OFF: OPEN
10 ZOOM-POSI
Zoom position signals
11 FOCUS-POSI
Focus position signal
12 SPARE
Standby (not used)
1
2
4
5
6
3
7
8
9
10
11
12
Panasonic part number K1AY112JA001
Maker part number
HR10A-10R-12SC(71)
(Hirose Denki)
START STOP START
+5 V
0 V
GPS
1
GPS TXA
Transmission data from the GPS unit to the camera
2
GPS RXA
Transmission data from the camera to the GPS unit
3
GPS VBAT
Backup power supply connector for the GPS unit
(DC 3.3 V)
4
REC START SW
Control signals of REC start/stop
5
GPS VCC
Power supply connector for the GPS unit (DC 3.3 V)
6
GPS GND
GND
1
2
4
5
6
3
Panasonic part number K1AY106J0001
Maker part number
HR10A-7R-6SC(73)
(Hirose Denki)
AJ-HPX3100G(VQT3A79)_E.book 151 ページ 2010年9月17日 金曜日 午後9時21分