10-5. DEW SENSOR
If excessive moisture or condensation is present inside the machine (an internal humidity of more than 98%) the unit will stop if
running. Until the moisture level decreases only the Eject mode will operate. To sense the humidity, a dew sensor is used. The
sensor is a special variable resistor, which change resistance ambient humidity.
The sensor range in resistance from about 5K ohm at 90% humidity to about 50K ohm at 98% humidity. Normally, the voltage
across the sensor is low because of its low resistance.
But if the moisture condenses inside the unit, the voltage at Dew terminal of SYSTEM CONTROL IC
increases to indicate
the
Dew condition.
Tape
Mode
Dew sensor ON
Dew sensor OFF
Power
Compulsory Power on
Power off
Dew indication
Indicate “d” and “U10”
Normal display
Cylinder
Rotate forcibly *1
Normal mode
Key operation
Not possible *2
Possible
OUT
Cassette in
Immediately a cassette is ejected after it
goes to cassette down position.
Possible
Power
Compulsory power on
Power off
Dew indication
Indicate “d” and “U10”
Normal display
Cylinder
Rotating *1
Normal mode
Key operation
Not possible *2
Possible
IN
Cassette condition
Shit to DOWN position and waits for
removing dew
Possible
*1: When the cylinder locks in dew mode, it will be released until dew sensor is turned off.
*2: The keys not relating to the tape running operation are able to used. Switching CH and Audio are effective.
Dew sensor on: During Dew formation is detected and 80 minutes after completion of Dew detection.
Dew sensor off: 80 minutes after completion of Dew detection, because the Dew Sensor dries faster than mechanism due to their
heat capacity.
10-6. SAFETY TIMER
10-6-1. Holding time of special playback and stand-by mode
Special playback and stand-by modes are automatically cancelled after fixed time, in order to protect tape and VCR. The table
below shows VCR mode and its holding time.
VCR Mode
Holding time
Mode after holding time has been over
STILL
Approx. 5 sec.
STOP
RSTILL
Approx. 2 sec.
STILL (PLAY position)
PAUSE(REC/ADUB/INSERT)
Approx. 5 min.
STOP
CUE/REV
Approx. 10 min.
PLAY
SLOW/RSLOW
Approx. 10 min.
STOP
STOP(Stand-by at PLAY position)
Approx. 5 min.
Stand-by at MID position.
Cylinder stops.
10-6-2. Detecting mechanism lock during mode shift
When the mode does not reach aimed position within certain time after the loading motor started, it is recognized as mechanism
lock and mechanism shifts to lock detection function.
Detecting time differs depends on in which timing lock has occurred. However, lock is detected within 5 sec. Maximum.
Mode change and action after lock is detected are as follows.
Mode change
Action and detecting lock
During cassette in
Cassette out
During cassette down
Cassette up Cassette out
During loading
Unloading Cassette out
FF STOP
l
Stop the loading motor once, and restart it for STOP
direction after 5 sec.
l
P-OFF when the second lock is detected.
Other mode changes
P-OFF immediately
Содержание NV-HV61GN
Страница 20: ...3 1 2 DETAIL OF DISASSEMBLY METHOD 1 REMOVAL OF THE TOP PANEL Remove 2 Screws A Remove 2 Screws B Fig D2 20 ...
Страница 21: ...2 REMOVAL OF THE BACK PANEL Remove 2 Screws C Remove Screw D Unlock 4 Tabs E Fig D3 21 ...
Страница 29: ...10 2 CASING PARTS SECTION 29 ...
Страница 30: ...10 3 PACKING PARTS SECTION 30 ...
Страница 31: ...11 REPLACEMENT PARTS LIST 31 ...
Страница 41: ...C4537 ECJ2VC1H560G CHIP CAPACITOR 41 ...
Страница 44: ...D2002 B0AAED000003 DIODE 44 ...
Страница 47: ...Q1152 2SC3311ASA TRANSISTOR 47 ...
Страница 49: ...R1502 ERJ3GEYJ273V CHIP RESISTOR 49 ...
Страница 54: ...W519 ERJ3GEY0R00V CHIP JUMPER 54 ...
Страница 109: ...4 1 3 PARTS NAME OF R4 MECHANISM Fig M2 ...
Страница 139: ...34 ...