![Panasonic MINAS-A5B Series Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/panasonic/minas-a5b-series/minas-a5b-series_technical-reference_278152050.webp)
No. SX-DSV02472 -
44-
4-6 Setting regenerative resistor
The table describes setup of regenerative resistor.
For details of regenerative resistor specification, refer to Technical Reference SX-DSV02201.
■ Parameters
Class
No.
At-
trib-
ute *1)
Title
Range
Unit
Function
0
16
C
External
Regenerative
resistor setup
0–3
—
With this parameter, you can select either to use the built-in
regenerative resistor of the driver, or to separate this built-in
regenerative resistor and externally install the regenerative resistor.
0: Use the built-in resistor and activate regenerative over-load
protection.
1: Use the external resistor and activate regenerative over-load
protection.
2: Use the external resistor but do not activate regenerative
over-load protection.
3: Do not use regenerative resistor. (Do not use over-load
protection.)
0
17
C
Selection of load
factor of external
regenerative
resistor
0–4
—
When selecting the external regenerative resistor (Pr 0.16 = 1, 2),
select the computing method of load factor of regenerative resistor.
0: Regenerative load factor is 100% when duty factor of external
regenerative resistor is 10%. (Compatible with A4N series)
1–4: For manufacturer’s use (do not setup)
*1) For parameter attribute, refer to Section 9-1.
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation