6.21.2 Saving a Base Position
The procedure for saving the current object position as a base position is described below. Before saving a base
position, set inspection conditions first and check to make sure that the object was detected after testing. When a
live image is displayed, a base position is saved after capturing a new image. When a memory image is
displayed, the current memory image is saved as a base position without capturing any image.
Registration Procedure:
1. Highlight the "Base Position" tab.
The cursor moves to "Base Setting".
2. Press the ENTER key.
When the dialog message "Register the base position?" appears,
choose "YES" to continue.
If the image correctly detected and the base position is saved, the
following data appear.
Under the Base Position tab
Adj. X: 0.0
Adj. Y: 0.0
Base Pos. X and Y:
The X and Y coordinates of the middle point of the line
connecting between the output points of the images
detected each in Area 1 and Area 2
Base Pos. Theta:
The angle that is created by the line connecting
between the output points of the images detected by
Areas 1 and 2 and X coordinate
In the Message area
Judgment: OK
Adj. X: 0.0
Adj. Y: 0.0
If the PV310 failed to detect object, the following message appears. Check the template image, size of
search area, etc.
E0042 Base position cannot be detected.
6.21.3 What To Do If You Faced a Trouble
Judgment result is always NG.
This is attributed to the following causes.
The object could not be detected
Recheck and reconsider the template image, the settings for search area size and the setting value for
sequence.
No base position is saved.
The error code "E0049" may be displayed.
Since any base position is not saved, the PV310 cannot work properly. Note that if you do the followings
after saving it, you need to save the base position again.
Position Adjustment checker that refers to adjustment amount cannot detect the object.
If Position Adjustment is saved as any number except "0", the adjustment amount of Position Adjustment
or Rotation Adjustment that is saved as the number is referred. If the Position Adjustment or Rotation
Adjustment checker failed to refer to the adjustment amount, it cannot detect the object. The PV310 does
not function properly and outputs "NG" result.
Содержание Micro-Imagechecker PV310
Страница 1: ......
Страница 9: ...1 Names and Functions of Parts Chapter 1 Chapter 1 Names and Functions of Parts ...
Страница 22: ......
Страница 23: ...15 Installation and Wiring Chapter 2 Chapter 2 Installation and Wiring ...
Страница 35: ...27 Input and Output Interface Ports Chapter 3 Chapter 3 Input and Output Interface Ports ...
Страница 47: ...39 Input and Output Interface Ports Chapter 3 Example of Wiring Connections with a PC IBM PC AT ANM81103 ...
Страница 63: ...55 Chapter 5 Procedure for Setting Inspection Conditions Chapter 5 Procedure for Setting Inspection Conditions ...
Страница 76: ......
Страница 107: ...99 Setting Checkers Chapter 6 6 7 Gray Edge 6 7 1 Menu Options ...
Страница 114: ...106 Setting Checkers Chapter 6 6 8 Feature Extraction 6 8 1 Menu Options ...
Страница 121: ...113 Setting Checkers Chapter 6 6 9 Smart Matching 6 9 1 Menu Options ...
Страница 137: ...129 Setting Checkers Chapter 6 6 11 Flaw Detection 6 11 1 Menu Options ...
Страница 207: ...199 TOOL Chapter 8 Chapter 8 TOOL ...
Страница 224: ......
Страница 225: ...217 Environment Settings Chapter 9 Chapter 9 Environment Settings ...
Страница 249: ...241 Chapter 10 Parallel Communication Chapter 10 Parallel Communication ...
Страница 265: ...257 Chapter 11 RS 232C Communication Chapter 11 RS 232C Communication ...
Страница 298: ......
Страница 299: ...291 Chapter 12 Ethernet Communication Chapter 12 Ethernet Communication ...
Страница 303: ...295 Chapter 13 Using a Compact Flash Memory Card Chapter 13 Using a Compact Flash Memory Card ...
Страница 323: ...315 Chapter 15 Troubleshooting Chapter 15 Troubleshooting ...
Страница 328: ......
Страница 329: ...321 Chapter 16 Camera Switching Unit Chapter 16 Camera Switching Unit ...
Страница 333: ...325 Chapter 17 General Specifications Chapter 17 General Specifications ...
Страница 340: ......
Страница 341: ...333 Chapter 18 Product Numbers Chapter 18 Product Numbers ...
Страница 347: ...339 Chapter 19 Dimensions Chapter 19 Dimensions ...
Страница 349: ...341 Chapter 19 Dimensions Double Speed Random Camera C Mount ANM831 Unit mm ...
Страница 352: ...344 Dimensions Chapter 19 ANM88281 ANM88081 ANM8804 ANM88161 ANM88251 Unit mm ...
Страница 356: ......
Страница 357: ...349 Chapter 20 Appendix Chapter 20 Appendix ...
Страница 358: ...350 Appendix Chapter 20 20 1 Pin Assignment of Camera Double Speed Random Camera ANM831 ...
Страница 359: ...351 Chapter 20 Appendix Standard Camera ANM832 ANM83203 ...
Страница 363: ...355 Record of Changes Manual No Date Revision detail ARCT1F456E March 2009 First Edition ...