1. Details of parameter
[Class 2] Damping control
Pr2.11
Title
4th notch width selection
Related
control mode
P S T F
Range
0 to 20
Unit
—
Default
2
Caution
Set the width of notch at the center frequency of the 4th notch filter.
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
When the applicable filter function is used, parameter value is automatically set.
Pr2.12
Title
4th notch depth selection
Related
control mode
P S T F
Range
0 to 99
Unit
—
Default
0
Caution
Set the depth of notch at the center frequency of the 4th notch filter.
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
When the applicable filter function is used, parameter value is automatically set.
Pr2.13
Title
Selection of damping filter switching
Related
control mode
P
S T
F
Range
0 to 3
Unit
—
Default
0
Among 4 filters select the filters to be used for damping control.
• When setup value is 0: Up to 2 filters can be used simultaneously.
•
When setup value is 1 or 2: Select the filter with external input(s) (VS-SEL1 and/or VS-SEL2).
Setup
value
VS-SEL2
VS-SEL1 1st damping 2nd damping 3rd damping 4th damping
0
—
—
1
—
—
2
• With setup value 3: Select the filter with command direction.
Setup
value
Position command
direction
1st damping 2nd damping 3rd damping 4th damping
3
Positive direction
Negative direction