4-14
Pr1.12
Title
Torque feed forward gain
Related
control mode
P S
T
F
Range
0 to 1000
Unit
0.1%
Default
0
• Multiply the torque command calculated according to the velocity control command by the
ratio of this parameter and add the result to the torque command resulting from the velocity
control process.
• Positional deviation at a constant acceleration/deceleration can be minimized close to 0 by
increasing the torque forward gain. This means that positional deviation can be maintained
at near 0 over entire operation range while driving in trapezoidal speed pattern under ideal
condition where disturbance torque is not active.
Pr1.13
Title
Torque feed forward filter
Related
control mode
P S
T
F
Range
0 to 6400
Unit
0.01ms
Default
0
Caution
• Set up the time constant of 1st delay filter which affects the input of torque feed forward.
• The torque feed forward will become effective as the torque feed forward gain is gradually
increased with the torque feed forward filter is set at approx. 50 (0.5 ms).
<Usage example of torque feed forward>
• To use the torque feed forward, correctly set the inertia ratio.
Use the value that was determined at the start of the real time auto tuning, or set the inertia
ratio that can be calculated from the machine specification to Pr0.04 Inertia ratio.
• The torque feed forward will become effective as the torque feed forward gain is gradually
increased with the torque feed forward filter is set at approx. 50 (0.5 ms).
• Positional deviation at a constant acceleration/deceleration can be minimized close to 0 by
increasing the torque forward gain. This means that positional deviation can be maintained
at near 0 over entire operation range while driving in trapezoidal speed pattern under ideal
condition where disturbance torque is not active .
Zero positional deviation is impossible in actual situation because of disturbance torque.
As with the velocity feed forward, large torque feed forward filter time constant decreases
the operating noise but increases positional deviation at acceleration change point.
Pr1.14
Title
2nd gain setup
Related
control mode
P S T F
Range
0 to 1
Unit
—
Default
1
Related page
Arrange this parameter when performing optimum adjustment by using the gain switching
function.
Setup value
Gain selection/switching
0
1st gain is fixed at a value. By using the gain switching input (GAIN), change
the velocity loop operation from PI to P.
GAIN input photo-coupler OFF PI operation
GAIN input photo-coupler ON P operation
*
The above description applies when the logical setting of GAIN input is
a-contact. ON/OFF of photo-coupler is reversed when b-contact.
1
Enable gain switching of 1st gain (Pr1.00-Pr1.04) and 2nd gain (Pr1.05-
Pr1.09).
For switching condition of the 1st and the 2nd, refer to P.5-17 "Gain Switching Function" of
Adjustment.
1. Details of parameter
[Class 1] Gain adjustment