4-20
Note
Related page
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.3-30... “Inputs and outputs on connector X4”
Pr2.05
Title
2nd notch width selection
Related
control mode
P S T F
Range
0 to 20
Unit
—
Default
2
Caution
Set the width of notch at the center frequency of the 2nd notch filter.
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
Pr2.06
Title
2nd notch depth selection
Related
control mode
P S T F
Range
0 to 99
Unit
—
Default
0
Caution
Set the depth of notch at the center frequency of the 2nd notch filter.
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
Pr2.07
Title
3rd notch frequency
Related
control mode
P S T F
Range
50 to 5000
Unit
Hz
Default
5000
Caution
Notch frequency is automatically set to the 1st resonance frequency estimated by the
adaptive filter.
In no resonance point is found, the frequency is set to 5000.
Pr2.08
Title
3rd notch width selection
Related
control mode
P S T F
Range
0 to 20
Unit
—
Default
2
Caution
Set the width of notch at the center frequency of the 3rd notch filter.
Higher the setup, larger the notch width you can obtain. Use with default setup in normal
operation.
When the applicable filter function is used, parameter value is automatically set.
Pr2.09
Title
3rd notch depth selection
Related
control mode
P S T F
Range
0 to 99
Unit
—
Default
0
Caution
Set the depth of notch at the center frequency of the 3rd notch filter.
Higher the setup, shallower the notch depth and smaller the phase delay you can obtain.
When the applicable filter function is used, parameter value is automatically set.
Pr2.10
Title
4th notch frequency
Related
control mode
P S T F
Range
50 to 5000
Unit
Hz
Default
5000
Caution
Notch frequency is automatically set to the 2nd resonance frequency estimated by the
adaptive filter.
The notch filter function will be invalidated by setting up this parameter to "5000".
1. Details of parameter
[Class 2] Damping control