Title of
signal
Alarm clear input
Related
control mode
P
S
T
F
Symbol
A-CLR
Default assignment
SI8
I/F circuit
SI 3-30
page
• Clears the alarm condition.
• This input cannot clear some alarms.
• For details, refer to P.6-3 When in Trouble “Protective function”, P.2-63 “(8) Alarm Display”
and P.7-25 “Display of Battery Alarm”.
Title of
signal
Command pulse inhibition input
Related
control mode
P
S
T
F
Symbol
INH
Default assignment
SI10
I/F circuit
SI 3-30
page
Caution
• Ignores the positional command pulse.
• When using this feature, set Pr5.18 “Invalidation of command pulse inhibition input” to 0.
This function can be assigned to only SI10. Allocation of this function to any other pin will
cause an error.
Title of
signal
Control mode switching input
Related
control mode
P
S
T
F
Symbol
C-MODE
Default assignment
SI9
I/F circuit
SI 3-30
page
Caution
• Selects a control mode.
This signal is required in all control modes. No setting will cause an error.
Title of
signal
Electronic gear (division/multiplication) switching input 1
Related
control mode
P
S
T
F
Symbol
DIV1
Default assignment
SI5
I/F circuit
SI 3-30
page
Title of
signal
Electronic gear (division/multiplication) switching input 2
Related
control mode
P
S
T
F
Symbol
DIV2
Default assignment
—
I/F circuit
SI 3-30
page
• Up to 4 numerators can be used for command dividing/multiplying by using DIV1 and DIV2.
<DIV1 and DIV2 vs numerator/denominator of selected command dividing/multiplying process>
DIV1
DIV2
Selected command dividing/multiplying process
Numerator
Denominator
OFF
OFF
Pr0.09
Pr0.10
ON
OFF
Pr5.00
Pr0.10
OFF
ON
Pr5.01
Pr0.10
ON
ON
Pr5.02
Pr0.10
Title of
signal
Damping control switching input 1
Related
control mode
P
S
T
F
Symbol
VS-SEL1
Default assignment
SI3
I/F circuit
SI 3-30
page
Title of
signal
Damping control switching input 2
Related
control mode
P
S
T
F
Symbol
VS-SEL2
Default assignment
—
I/F circuit
SI 3-30
page
Note
• Selects applicable frequency for damping control.
Combination of damping control input changeover 1 and 2 (VS-SEL1, VS-SEL2) enables
select of max. 4 options.
Also refer to P.4-21 “Pr2.13 [Damping filter switching selection]”.
4. Inputs and outputs on connector X4
Input Signal and Pin No.
Содержание MADHT1105
Страница 36: ...1 24 MEMO ...
Страница 118: ...2 82 MEMO ...
Страница 168: ...3 50 MEMO ...
Страница 272: ...5 42 MEMO ...
Страница 351: ...7 55 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...
Страница 367: ...7 71 1 Before Using the Products 2 Preparation 3 Connection 4 Setup 5 Adjustment 6 When in Trouble 7 Supplement MEMO ...