70
Screen Description
Time (HH:MM:SS):
Displays time of internal clock.
Date
(YYYY/MM/DD):
Displays date of internal clock.
SNTP Server IP
Displays an IP address of SNTP server that executes time
synchronization.
SNTP Polling Interval
Displays an interval of time synchronization with SNTP server.
Time Zone:
Displays time zone.
Daylight Saving:
Displays the application status of Daylight Saving (Summer time).
Available commands are listed below.
C Set time of internal clock of this Switching Hub.
Press "C." The command prompt changes to "Enter Date(Year) >" and enter a year.
Then, the command prompt changes to "Enter Date(Month) >" and enter a
month. Then, the command prompt changes to "Enter Date(Day) >" and enter a
day. Then, the command prompt changes to "Enter Time(Hour) >" and enter an
hour. Then, the command prompt changes to "Enter Time(Minute) >" and enter a
minute. Then, the command prompt changes to "Enter Time(Sec) >" and enter a
second.
P Set an IP address of SNTP server.
Press "P." The command prompt changes to "Enter new IP address>." Enter an IP
address of SNTP server.
I Set an interval time for SNTP synchronization.
Press "I." The command prompt changes to "Enter Interval Time>." Enter an
interval of time synchronization with SNTP server with a value of 1 to 1440
(minutes).
The factory default setting is 1440 minutes (1 day).
E Set the application of Daylight Saving (Summer time).
Press "E." The command prompt changes to "Enable or Disable Daylight Saving
(E/D)>." Enter "E" to apply, or "D" not to apply Daylight Saving.
But, in case time zone is set to where daylight saving is not applied, this
configuration is not available.
When this Switching Hub is used domestically, this configuration is not required.
Z Set time zone.
Press "Z" to open a list of time zones. Specify a time zone you wish to set.
The factory default setting is "(GMT+09:00) Osaka, Sapporo, Tokyo."
Q Return to the previous menu.
Note: In case SNTP server is located outside of firewall, connection with
SNTP server may not be possible depending on settings by system
administrator.
For details, ask to your system administrator.
If you wish to disable time synchronization function, set SNTP server
IP to 0.0.0.0 and reboot the device.
Содержание M24PWR
Страница 5: ...5 malfunction When stacking Switching Hubs leave a minimum of 20 mm space between them is required ...
Страница 24: ...24 command If you enter a command or setting not available an error message is shown in the explanation field ...
Страница 26: ...26 ...
Страница 32: ...32 ...
Страница 45: ...45 ...
Страница 65: ...65 ...
Страница 74: ...74 Quit to previous menu Quits the Advanced Switch Configuration Menu and returns to the Main menu ...
Страница 77: ...77 setting and the management VLAN status of VLAN ID 1 is UP ...
Страница 92: ...92 Press S Q Return to the previous menu ...
Страница 94: ...94 ...
Страница 118: ...118 Q Return to the previous menu ...
Страница 121: ...121 ...
Страница 126: ...126 ICMP Type Displays the ICMP type ...
Страница 132: ...132 802 1p Priority Displays priority of IEEE802 1p TCP SYN Flag Displays the TCP SYN flag ICMP Type Displays ICMP type ...
Страница 152: ...152 Threshold Displays the threshold of the number of packets per second ...
Страница 169: ...169 Fig 4 7 49 Display of values accumulated after resetting the counters ...
Страница 181: ...181 Q Return to the previous menu ...
Страница 207: ...207 Q Return to the previous menu ...
Страница 228: ...228 RSTP MIB IEEE 802 1w IEEE8021 PAE MIB IEEE802 1X IEEE8023 LAG MIB IEEE 802 3ad ...
Страница 233: ...233 IEEE 802 3af standard ...