Installation Manual
The first digit indicates the communications status with the Network Adaptor.
■
If the Communications with the Network Adaptor are not Functioning
9-3. Checking the Network Adaptor Communications
■
Operation Procedure
•
Press "CLOCK (▼)"+"DATA (▲)" for three seconds in the normal state to open the status selection mode.
•
Press "DATA (▲)" or "CLOCK (▼)" to display the system status (S1).
•
•
[ ] indicates that the communications with the Network Adaptor is operating normally; and [ ]appears if it is not
in operation. Make sure that the display for the 1st digit turns to [ ].
•
The Network Adaptor may not be running. Check whether the protection device for Network Adaptor is turned ON.
•
The communications line may be connected incorrectly. Check chapter 6-1 in the "Installation" section again and
verify that the communications line is connected correctly to both the Network Adaptor and the storage battery
system.
Stopped (Grid-connected)
Stopped (Stand-alone)
Status 2
Status 1
Status 3
ュモヵモ
ヤロヰヤレ
or
ュモヵモ
ヤロヰヤレ
or
ュモヵモ
ヤロヰヤレ
or
Status Selection
Normal State
ヰワバ
ヰョョ
ヤモワヤユロ
1 sec
3 sec
ヤロヰヤレ
+
: OK(Normal state)
: NG (Error state)
1st digit : Network Adaptor Communication Status
2nd digit : AC Voltage Status
3rd digit : DC Voltage Status
10.Complete Settings
The settings are now complete.
Attach the front lid by referring to P.26.
When connecting the Network Adaptor, refer to the Setting Manual which is included with the Network Adaptor, then
perform the settings. Finally, cut "Emergency Response Measures sheet" below and put it and "Stop procedure label"
in a prominent position near the battery storage system.
[ FIRST-AID MEASURES]
Spilled internal cell materials
Inhalation : Make the victim blow his/her nose, gargle. Seek medical attention if necessary.
Skin contact : Remove contaminated clothes and shoes immediately. Wash extraneous matter or contact
region with soap and plenty of water immediately.
Eye contact : Do not rub one’ s eyes. Immediately flush eyes with water continuously for at least 15 minutes.
Seek medical attention immediately.
A battery cell and spilled internal cell materials
Ingestion : Make the victim vomit. When this is not possible or feeling unwell after vomiting, seek immediate
medical attention.
[FIRE-FIGHTING MEASURES]
Suitable extinguishing media : Plenty of water, carbon dioxide gas, nitrogen gas, chemical powder fire
extinguishing medium and fire foam.
Specific hazards : Corrosive gas may be emitted during fire.
Specific methods of fire-fighting : When the battery burns with other combustibles simultaneously, take
fire-extinguishing method which correspond to the combustibles. Extinguish a fire from the windward as much
as possible.
Special protective equipment for firefighters :
Respiratory protection : Respiratory equipment of a gas cylinder style or protection-against-dust mask
Hand protection : Protective gloves
Eye protection : Goggle or protective glasses designed to protect against liquid splashes
Skin and body protection: Protective cloth
[ACCIDENTAL RELEASE MEASURES]
Spilled internal cell materials, such as electrolyte leaked from a battery cell, are carefully dealt with according to
the followings.
Precautions for human body: Remove spilled materials with protective equipment (protective glasses and
protective gloves). Do not inhale the gas as much as possible. Moreover, avoid touching with as much as
possible.
Environmental precautions: Do not throw out into the environment.
Method of cleaning up: The spilled solids are put into a container. The leaked place is wiped off with dry cloth.
Prevention of secondary hazards: Avoid re-scattering. Do not bring the collected materials close to fire.
Emergency Response Measures