7-16.Fixed Reactive Factor Setting
※
This mode is enabled only when it is set to the MODE3 as described in Chapter 7-13.
・
While the power inputs the inverter, the reactive factor is set "0[var]".
・
While the inverter outputs the power, the reactive power is fix and the maximum ratio of reactive power (vars) to
rated apparent power should be 60%.
■
Preparation
• See 7-2 and switch to the Parameter Item Selection mode showing the initial display [no4.12].
■
Operation Procedure
• While [no4.12] is displayed, press "MENU (ENTER)" to switch to the Parameter Display mode.
• While the Parameter Display mode is selected, press "DATA(▲)" or "CLOCK(▼)" and select the parameter item.
Then press "MENU (ENTER)" to switch to the Parameter Setting mode. Or press "ON/OFF (CANCEL)" to return
to the Parameter Item selection.
• While the Parameter Setting mode is selected and digits are blinking, press "DATA(▲)" or "CLOCK (▼)" and
adjust the parameter level.
• After the adjustment of the parameter level, press "MENU (ENTER)" to fix the parameter level. Or press "ON/OFF
(CANCEL)" to cancel. Then return the Parameter Display mode.
• After returning the Parameter Display mode, press "ON/OFF (CANCEL)" to return the Parameter Item Selection.
Parameter Item
Default Set Point
Range
Parameter
Selection Display
1.00
LAGG
0.80
〜
1.00
LAGG
/LEAD
fix
Reactive Factor
fix
Source or Sink
Table
Fixed Reactive Factor Setting
Fixed Reactive
Factor Setting
Parameter Display Mode
Parameter Item Selection
Parameter Setting Mode
Reactive Factor Setting
Reactive Factor Setting
or
Source or Sink Setting
Source or Sink Setting
or
Australia/New Zealand
or
or
or