78
Installation Manual
7-9. Multiple Inverter Combinations Setting
In this setting mode, parameter during Multiple inverter operation can be set.
Inverter ID that be set as ’ 01’ is the parent machine. Its parent machine looks for Battery systems according with
set value at (G2).
Notics:
・
Parent machine does not mather anywhere on the connection of system line (see Chapter 1-1
◎
Installation of
multiple system).
・
When "00 : Disabled" is set, the number of connection (G2) is ignored.
・
If Multiple Inverter combination setting is not set properly, erroe code "U110" will be displayed 24 hours after start
working.
・
Parent machine is set only one.
・
Please do not set as the parent machine in two or three.
・
Make sure the number of connection is correct.
Parameter Item
Default Set Point
Range
Parameter
Selection Display
00:Disabled
1
00:Disabled
01:PCS1
02:PCS2
03:PCS3
1
〜
3
Connection
State and ID Number (G1)
The Number of
Connection (G2)
Table
Multiple Inverter Combinations
Australia/New Zealand
Single
System
G1
G2
No.1 No.2 No.3
00
-
-
1
-
-
No.1 No.2 No.3
01
02
-
2
2
-
No.1 No.2 No.3
01
02
03
3
3
3
Double
riple
Table
Setting
ample