A
•
Perform the following steps:
1.
On the
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution
screen, enter the floating extension number you chose
2.
Click
Apply
.
3.
11.5.1.1 PBX Configuration—[3-5-1] Group—Incoming Call
Distribution Group—Group Settings—Member List
screen, select the ICD
group you created from the
ICD Group No.
drop-down list.
4.
Enter the extension numbers of member extensions in the
5.
Click
Apply
.
6.
18.2 PBX Configuration—[10-2] CO & Incoming
Call—DIL Table & Port Settings
screen, enter the floating extension number of
the ICD group as the
DIL Destination—Day, Lunch, Break, Night
mode.
7.
Modify other settings as required from the
Group—Incoming Call Distribution
Group
submenu.
Q
How do I set the queuing operation for an Incoming Call Distribution group?
A
•
Perform the following steps:
1.
On the
11.5.2 PBX Configuration—[3-5-2] Group—Incoming Call Distribution
screen, set the actions as required for each
queuing table.
2.
On the
11.5.1 PBX Configuration—[3-5-1] Group—Incoming Call Distribution
tab, select the
number of the Queuing Time Table to use in each time mode.
Q
How do I add an extension as a member of an Incoming Call Distribution (ICD)
group?
A
•
Perform the following steps:
1.
11.5.1.1 PBX Configuration—[3-5-1] Group—Incoming Call
Distribution Group—Group Settings—Member List
screen, from the
ICD
Group No.
drop-down list, select the group you want to modify.
The ICD group must have an extension number set.
2.
Enter the extension number of the extension you want to add in a blank cell of the
column.
3.
Set
4.
Click
Apply
.
Note that it is necessary to set the extension number of the ICD group in advance.
Q
I have set FWD through system programming, but calls are still not being forwarded.
A
•
Perform the following steps:
1.
Check that the
Forward / DND
settings of the target extension on the
Configuration—[4-1-2] Extension—Wired Extension—FWD/DND
12.2.2 PBX Configuration—[4-2-2] Extension—Portable Station—FWD/
DND
screen are set to one of the forwarding settings.
2.
Create a FWD button on the target extension if one does not already exist.
3.
Press the FWD button so that it changes to FWD status.
PC Programming Manual
49
2.3 Frequently Asked Questions (FAQ)
Содержание KX-NS500
Страница 12: ...12 PC Programming Manual Table of Contents ...
Страница 13: ...Section 1 Overview This section provides an overview of programming the PBX PC Programming Manual 13 ...
Страница 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Страница 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Страница 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Страница 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Страница 56: ...56 PC Programming Manual 3 1 Home Screen ...
Страница 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Страница 142: ...142 PC Programming Manual 7 12 Utility CS Web Connection ...
Страница 456: ...5 1 4 Time Service 456 PC Programming Manual 10 4 1 PBX Configuration 2 4 System Week Table Time Setting ...
Страница 459: ...Feature Guide References 5 1 4 Time Service PC Programming Manual 459 10 5 PBX Configuration 2 5 System Holiday Table ...
Страница 552: ...552 PC Programming Manual 10 11 2 PBX Configuration 2 11 2 System Audio Gain Card ...
Страница 576: ...5 1 2 Group 576 PC Programming Manual 11 4 PBX Configuration 3 4 Group Paging Group ...
Страница 607: ...Feature Guide References 5 2 4 2 PS Ring Group PC Programming Manual 607 11 8 PBX Configuration 3 8 Group PS Ring Group ...
Страница 736: ...736 PC Programming Manual 12 3 1 PBX Configuration 4 3 Extension DSS Console DSS key data copy ...
Страница 758: ...758 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Страница 810: ...810 PC Programming Manual 17 5 PBX Configuration 9 5 Private Network Centralised UM VM Unit ...
Страница 828: ...828 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Страница 850: ...850 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Страница 884: ...884 PC Programming Manual 20 1 3 UM Configuration 1 3 Mailbox Settings Auto Configuration ...
Страница 908: ...908 PC Programming Manual 22 2 UM Configuration 3 2 UM Extension Trunk Service Port Assignment ...
Страница 976: ...976 PC Programming Manual 26 1 UM Configuration 7 System Security ...
Страница 1007: ...Feature Programming References PC Programming Manual 1007 ...