9.36 PBX Configuration—[1-4] Configuration—Clock
Priority
Shelf-Slot Number
Selects and prioritises slot numbers for PRI cards that are used to forward a clock pulse from an external
source to the PBX.
Obtain the master clock time from the outside line that the telephone company provides.
To change Clock Priority, follow the steps below:
1.
Assign a Clock Priority to each slot.
2.
Set the status of the present clock source card to "
OUS
", then "
INS
".
Note
If multiple PBXs are used to establish a private network (TIE line service, QSIG network, etc.) without being
connected through the telephone company, assign only one PBX as the clock source on the network. That
PBX should have a card connected to a telephone company line selected as its clock source. All other
PBXs should have cards connected to the network selected as the clock source. This enables all PBXs on
the network to synchronise their timing.
Value Range
None, Shelf and Slot number
Shelf and slot numbers are listed using the pattern "X-Y":
•
X: Shelf number 14
–
1: KX-NS300/KX-NS500 basic unit
–
2: Expansion Unit1
–
3: Expansion Unit2
–
4: Expansion Unit3
•
Y: Slot number (1–7)
Maintenance Console Location
9.36 PBX Configuration—[1-4] Configuration—Clock Priority
420
PC Programming Manual
9.36 PBX Configuration—[1-4] Configuration—Clock Priority
Содержание KX-NS500
Страница 12: ...12 PC Programming Manual Table of Contents ...
Страница 13: ...Section 1 Overview This section provides an overview of programming the PBX PC Programming Manual 13 ...
Страница 18: ...Table 2 For NE model 18 PC Programming Manual 1 1 3 Entering Characters ...
Страница 19: ...Table 3 For RU UC model PC Programming Manual 19 1 1 3 Entering Characters ...
Страница 20: ...Table 4 For Greece 20 PC Programming Manual 1 1 3 Entering Characters ...
Страница 50: ...50 PC Programming Manual 2 3 Frequently Asked Questions FAQ ...
Страница 56: ...56 PC Programming Manual 3 1 Home Screen ...
Страница 74: ...74 PC Programming Manual 5 4 System Control System Shutdown ...
Страница 142: ...142 PC Programming Manual 7 12 Utility CS Web Connection ...
Страница 456: ...5 1 4 Time Service 456 PC Programming Manual 10 4 1 PBX Configuration 2 4 System Week Table Time Setting ...
Страница 459: ...Feature Guide References 5 1 4 Time Service PC Programming Manual 459 10 5 PBX Configuration 2 5 System Holiday Table ...
Страница 552: ...552 PC Programming Manual 10 11 2 PBX Configuration 2 11 2 System Audio Gain Card ...
Страница 576: ...5 1 2 Group 576 PC Programming Manual 11 4 PBX Configuration 3 4 Group Paging Group ...
Страница 607: ...Feature Guide References 5 2 4 2 PS Ring Group PC Programming Manual 607 11 8 PBX Configuration 3 8 Group PS Ring Group ...
Страница 736: ...736 PC Programming Manual 12 3 1 PBX Configuration 4 3 Extension DSS Console DSS key data copy ...
Страница 758: ...758 PC Programming Manual 13 5 PBX Configuration 5 5 Optional Device External Sensor ...
Страница 810: ...810 PC Programming Manual 17 5 PBX Configuration 9 5 Private Network Centralised UM VM Unit ...
Страница 828: ...828 PC Programming Manual 18 4 PBX Configuration 10 5 CO Incoming Call Miscellaneous ...
Страница 850: ...850 PC Programming Manual 19 3 PBX Configuration 11 3 Maintenance Air Synchronisation ...
Страница 884: ...884 PC Programming Manual 20 1 3 UM Configuration 1 3 Mailbox Settings Auto Configuration ...
Страница 908: ...908 PC Programming Manual 22 2 UM Configuration 3 2 UM Extension Trunk Service Port Assignment ...
Страница 976: ...976 PC Programming Manual 26 1 UM Configuration 7 System Security ...
Страница 1007: ...Feature Programming References PC Programming Manual 1007 ...