1.
Turn on DIP switch no. 4 and turn off DIP switches no.
6 and no. 8.
2.
Restart the unit.
3.
Start IP Terminal Maintenance Console.
For details about IP Terminal Maintenance Console,
refer to "5.12 IP Terminal Maintenance Console".
a.
Click Setting three times.
b.
On the Configure IP Terminal Setting screen, if the
PBX Address (Primary) and PBX Address
(Secondary) fields are empty, set the appropriate
IP addresses.
4.
Restart the unit.
Note
If an activation key (KX-NSE201/KX-NSE205/KX-NSE210/KX-NSE220) is installed on the primary PBX,
the same activation key must also be installed on the secondary PBX.
5.11 Firmware update of the proprietary PSs
The firmware of the proprietary PSs (KX-TCA185/KX-TCA285/KX-TCA385 only) can be updated via the unit.
There are two methods to download the firmware from the unit.
Step 1: Firmware download from KX-NS series PBX to the unit
The download method is specified by using the Web Maintenance Console.About the details, refer to the
manual of the PBX.
Step 2: Firmware download from the unit to the PSs
1.
After starting the download mode, "Searching" is blinking on the LCD of the PS.
2.
When finding the CS, "Please Wait..." is blinking while trying to connect the CS.
3.
If the connection succeeded, the firmware information is displayed.
4.
When starting the download, "Downloading xx%" is displayed.
xx: progress ratio
5.
When the download completed, "Download OK" is displayed.
Note
•
PS restarts several times during updating the firmware.
•
PS firmware updates can be performed simultaneously for up to 4 PSs per CS.
•
PS firmware downloading can be performed during regular operation.
5.12 IP Terminal Maintenance Console
IP Terminal Maintenance Console has the following two features.
•
LAN synchronization diagnosis feature
Sets and controls LAN synchronization diagnosis and outputs the diagnosis results.
For details about the diagnosis results, refer to the following table.
•
Local setting feature
Installation Guide
69
5 Appendix