7.
a.
Highlight IP-CSs and click the right arrow to select
them for registration.
b.
Click Next. A screen will appear with information on
the selected IP-CS for programming.
Note
•
If the IP-CS has been connected to the LAN
and power has been turned on, the IP
address of the PBX will be assigned
automatically.
•
If not, connect the IP-CS to the LAN and
turn the power on within 15 minutes after
this operation is done. The IP address of
the PBX will then be assigned
automatically.
c.
If the registration is still in progress, the dialogue
box will show "Registration Executing".
If the registration is successful, the dialogue box
will show "Registration Completed". Click Close.
8.
Click a cell in the Connection column for the registered
CS to open the Command window for the port. In the
Command window, click OUS to change the status of
the port to "OUS".
9.
(Air synchronization only)
From the Air Sync Group No. drop-down list, select the
desired Air Synchronization Group number.
10.
Click Apply.
11.
Click the cell in the Connection column again, and click
INS in the Command window to return the status of the
port to "INS".
Once the IP-CS is successfully registered, the status of the IP-CS will update to show "Registered".
Note
(Air synchronization only)
When you need to change the Master CSs (Master CS1 and Master CS2) to different CSs, refer to
"Assigning the Synchronizing CSs".
De-registering the IP-CS
When uninstalling an IP-CS that has been installed once, de-register the IP-CS.
Note
When uninstalling IP-CSs that are supplying the clock signal, air synchronization is lost. If there is an IP-CS
that is synchronized with the IP-CS that is being uninstalled, reconstruct the air synchronization tree
beforehand so that the uninstalled IP-CS is not supplying the clock signal to any IP-CSs.