LED Indications
Color
Status
Green (4 channels —
without activation
key
*1
)
ON
Stand-by (no active calls)
Slow Flashing
Talking (active calls, channels available)
Moderate Flashing
All channels busy
Blue (8 channels —
with activation key
*1
)
ON
Stand-by (no active calls)
Slow Flashing
Talking (active calls, channels available)
Moderate Flashing
All channels busy
Amber
ON
Stand-by (unstable air/LAN synchronization [no active
calls])
Slow Flashing
Talking (unstable air/LAN synchronization [active calls])
Moderate Flashing
All channels busy (unstable air/LAN synchronization)
Red
ON
Fault
Slow Flashing
Out of service or starting up (from data link
establishment to air/LAN synchronization)
Moderate Flashing
Starting up (communication with the PBX not
established)
Red and green
Alternate blinking
Site survey master mode
OFF
Power off or updating the firmware
*1
Refer to "Optional Accessories".
Note
LED flashing patterns are as follows:
•
Slow Flashing: 60 times per minute
•
Moderate Flashing: 120 times per minute
RESET Switch
Pressing the RESET switch allows you to return the unit to its factory default settings, perform site survey mode
operations or perform advance diagnosis mode operations.
Operation
Description
Pressing and holding the RESET switch for 10
seconds when the unit is on.
Returns the unit to its factory default settings.
Pressing and releasing the RESET switch in site
survey mode.
Makes the unit a slave CS for the site survey.
Pressing the RESET switch again returns the unit to a
Master CS.
For details about performing the site survey, refer to
"3.3 Site Survey".
Installation Guide
13
2 Overview