Switch
Description
8
•
Set to ON when starting up in LAN synchronization diagnosis mode.
•
Set to OFF when starting up in normal mode.
*1
This unit can temporarily switch its connection from a primary PBX to a secondary PBX when a communication path fault occurs to
the primary PBX. This allows the unit to continue operating without interruption. To enable this feature, you must register the IP
address of the secondary PBX on the unit in advance. For details, refer to the Installation Manual for your PBX.
DIP Switch Settings
The following tables describe various DIP switch configurations.
Note
0: OFF, 1: ON
Specifying the site survey channel
Specify a site survey channel when using a PS other than a KX-TCA185/KX-TCA285/KX-TCA385.
DIP Switch
Site Survey Channel
1
2
3
4
5
6
7
8
KX-NS0154
KX-NS0154CE/
KX-NS0154LA
0
0
0
1
1
0
0 ch
2 ch
1
0
0
1
1
0
1 ch
3 ch
0
1
0
1
1
0
2 ch
4 ch
1
1
0
1
1
0
3 ch
5 ch
0
0
1
1
1
0
4 ch
6 ch
1
0
1
1
1
0
0 ch
7 ch
0
1
1
1
1
0
1 ch
8 ch
1
1
1
1
1
0
2 ch
9 ch
Channel for automatic site survey
Use this setting when using a KX-TCA185/KX-TCA285/KX-TCA385 PS.
DIP Switch
Description
1
2
3
4
5
6
7
8
0
1
0
Setting for a KX-TCA185/KX-TCA285/
KX-TCA385.
Time Required for Long-Term Diagnosis
DIP Switch
Time
1
2
3
4
5
6
7
8
0
0
0
1
1
1 day (24 hours)
1
0
0
1
1
2 days (48 hours)
Installation Guide