5.7 Synchronization with Traditional CSs or Old
IP-CSs
When traditional CSs are connected via a stacking connection
Assign and locate one of traditional CSs to Air Sync Master of the Air Sync Group.
IP-CS (KX-NS0154 and KX-NCP0158) only can be the slave CS, as shown in the following figure. LAN
Synchronization is not available in this case.
Note
•
Air Sync Master is also a member of Air Sync Group 1, so maximum 15 IP-CSs are available in this
Group.
•
In order to cover the same area, the required number of air synchronized IP-CS may be larger than
that of traditional CSs, or LAN synchronized KX-NS0154.
Air Sync Group 1
: PBX
: Traditional CS
: Traditional CS (Air Sync Master)
: KX-NS0154
62
Installation Guide
5 Appendix