5.2 DIP Switch
The unit has 8 DIP switches, which can be used to enter the following operation modes.
DIP Switch
ON
OFF
1
2
3
4
5
6
7
8
Note
•
All switches are turned off by default and should be in this state during normal operation.
•
The unit must be restarted to enable changes to DIP switches.
Switch
Description
1–3
When switches 4 and 6 are on and switch 8 is off
Specifies the channel number used for the site survey by using PS.
®
Specifying the site survey channel
When switches 4 and 8 are on
Specifies the time required for long-term LAN synchronization diagnosis.
®
Time Required for Long-Term Diagnosis
4
When switch 6 is on and switch 8 is off
•
Set to ON when performing a site survey using a PS other than KX-TCA185/
KX-TCA285/KX-TCA385.
•
Set to OFF when performing a site survey using a KX-TCA185/KX-TCA285/
KX-TCA385.
When switches 6 and 8 are off
•
Set to ON when starting up in Secondary PBX connection mode
*1
.
•
Set to OFF when starting up in normal mode.
When switch 8 is on
•
Set to ON when starting up in long-term LAN synchronization diagnosis mode.
•
Set to OFF when starting up in short-term LAN synchronization diagnosis mode.
5
•
Set to ON when performing air synchronization in a site survey.
•
Set to OFF when performing LAN synchronization in a site survey.
6
•
Set to ON when performing a site survey.
•
Set to OFF when starting up in normal mode.
7
•
Set to ON when starting up in static IP mode.
•
Set to OFF when starting up in DHCP/Static normal mode.