1.13 P
198
Feature Manual
[DPT + SLT]
•
When in the parallel mode, XDP mode of the Super Hybrid port should be turned off through system
programming.
•
Whether the SLT rings for incoming calls is programmable.
Ring on:
Both telephones ring when a call is received, except for when the digital proprietary telephone
(DPT) is in Hands-free Answerback mode (
→
1.8.1 Hands-free Answerback) or voice-calling mode
(Alternate Receiving Ring/Voice) (
→
Ring off:
Only the DPT rings when a call is received, however, the SLT can be used to answer the call.
•
Both telephones cannot engage in calls simultaneously. If one telephone goes off-hook while the other
is on a call, the call is switched to the telephone that goes off-hook. Note, however, that the call will not
be switched when the telephone is:
a)
Being monitored by another extension. (
→
b)
Receiving an Off-hook Call Announcement (OHCA) (
→
Announcement)) or Whisper OHCA. (
→
c)
On a conference call (
→
→
1.5.3 Executive Busy Override,
→
d)
Using Live Call Screening (LCS) or Two-way Record is activated (
→
1.19.4 Voice Mail DPT (Digital)
[DPT + DPT]
•
Available Telephones
KX-T7600 series, except KX-T7640
•
When Digital XDP connection enables the number of DPTs to exceed the maximum capacity that the
PBX supports, the following conditions must be met:
–
KX-TDA50: An MEC card is installed and an additional AC adaptor is connected.
–
KX-TDA100/KX-TDA200: An MEC card and the PSU-M or PSU-L is installed.
–
KX-TDA600: The PSU-L is installed.
•
The following features cannot be used on either the master or slave DPT:
a)
OHCA: A call waiting tone will be heard even if the OHCA feature is set.
b)
USB Module: The DPTs will not function properly if a USB Module is attached to either DPT. Do
not connect a USB Module to either of the DPTs.
Note
To cancel a Digital XDP connection, disconnect the slave DPT from the master, then disconnect the
and reconnect the master DPT to the PBX.
[DPT + DPT + SLT]
•
When an SLT is connected to the slave DPT in parallel mode, the SLT acts as a parallel extension of
the master DPT. If connected in XDP mode, the SLT acts as an independent extension.
Installation Manual References
KX-TDA50
2.6.2 Parallel Connection of the Extensions
2.6.3 Digital EXtra Device Port (Digital XDP) Connection
KX-TDA100/KX-TDA200
Содержание HYBRID IP-PBX KX-TDA100
Страница 14: ...14 Feature Manual...
Страница 15: ...Feature Manual 15 Section 1 Features and Configurations...
Страница 91: ...1 4 D Feature Manual 91 Operating Manual References 1 3 21 Doorphone Call...
Страница 340: ...1 20 W 340 Feature Manual...
Страница 341: ...Feature Manual 341 Section 2 Appendix...
Страница 357: ...Feature Manual 357 Index...
Страница 362: ...Index 362 Feature Manual X XDP EXtra Device Port 98 XDP Digital 197 XDP Wireless 337...