Introduction
Introduction
17
16
3.6 Internal Terminals in Wiring Box
NOTE!
Not all communication wirings connected with the terminals on the
communication board are shown in the picture.
Refer to the Section 6 for the details on communication connection.
Item
A
B
C
D
E
H
F
G
Description
AC terminals
Grounding bar
PV terminals
COMM in terminal
MLPE terminal
COMM out terminal
AUX terminal
Battery terminals
A
B
E
F
C
B
H
G
D
3.7 Identification of EVERVOLT Hybrid Inverter
A1-7.0-US
A1-6.0-US
076
AH2
E
7
0
0
1
Model
Power
Year
Month Work Order Number
Serial Number
0
0
1
1. Every EVERVOLT Hybrid Inverter product corresponds to a unique serial
number. The serial number is divided into five parts: type (3 bits)+ power (3 bits)+
year/month (2 bits)+ work order number (3 bits)+ stream number (3 bits), a total of
14bits.
EVERVOLT Hybrid Inverter
076: Power ----7.6 KW;
E: Year ------ I:2022 (A:2014; B: 2015......)
7: Month ------ July (October :A, November ;B, December......)
001: Work order number---- 001:001~999 (Monthly zero clearing)
001: Serial number---- 001:001~ZZZ (will be cleared for next work order).
Model
Parameter
Serial NumberIdentification
PV INPUT
EVERVOLT HYBRID INVERTER
Model: EVHB-I7
Max. DC Voltage
Operating Voltage range
No. of MPPT/String per MPPT
Max. DC Current per MPPT
Max. DC Power
550 Vd.c.
90-500 Vd.c.
3/1
16 A
11400 W
BATTERY
Battery Type
Li-ion
GRID OUTPUT/ INPUT
Nominal AC Voltage
Max. Continuous Current
Max. Continuous AC Power
Nominal AC Frequency
Operating Frequency Range
AC Output Power Factor
120/240 Vac split phase
31.7 A
7608 VA
60 Hz
59.3 Hz-60.5 Hz
0.8 Leading- 0.8 Lagging
OTHER
MADE IN CHINA
320301174702
Max. DC Current per MPPT
Max. DC Power
16 A
11400 W
BATTERY
Battery Type
Nominal DC Voltage
DC Operating Voltage Range
Max. Charge / Discharge Current
Li-ion
150 Vd.c.
75-450 Vd.c.
54 A / 54 A
Enclosure Type
Operating Temperature
UL 1741/ UL 1699B
CSA107.1
Type 4X
-13˚F~+140˚F
no derating below 113˚F
GRID OUTPUT/ INPUT
Nominal AC Voltage
Max. Continuous Current
Max. Continuous AC Power
Nominal AC Frequency
Operating Frequency Range
AC Output Power Factor
120/240 Vac split phase
31.7 A
7608 VA
60 Hz
59.3 Hz-60.5 Hz
0.8 Leading- 0.8 Lagging
LISTED
intergrated
PV AFCI
TYPE 1
605129
2. The standard series number rules is as follows:
Содержание EVERVOLT EVHB-I7
Страница 1: ...320101067100...