background image

XR56 SMARTSafe

TM

XR56 SMARTSafe

TM

1

www.avtronencoders.com

Nidec Industrial Solutions

 

243 Tuxedo Avenue  |  Cleveland, Ohio 44131 

 

[email protected]

+1 216-642-1230

4 1/2” C-FACE MOUNT MODULAR 
FOR HAZARDOUS APPLICATIONS

ENCODER INSTRUCTIONS

Rev: 09-15-2020

DESCRIPTION

The Avtron XR56, SMARTSafe™ is a modular, two piece incremental 

encoder for hazardous atmosphere applications. It provides a two phase, A 

Quad B frequency (pulse) output, with complements. The XR56 mounts on 

a 4.5” (NEMA 56C) Face.

 CAUTION

 

The XR56 is designed for use in hazardous applications 

 

which require protection from gas or dust ignition for 

 

safe operation.  Proper selection, wiring and installation 

 

procedures are essential to ensuring safe conditions.

Because the XR56 is modular, there are no bearings or couplings required. 

This, combined with the latest magneto resistive (MR) sensor technology, 

allows the XR56 to provide superior mechanical performance and 

increased reliability.

An Avtron XR56 can be configured with one or two independent outputs. 

Each output has six signals: (A, B) 90° out of phase, with complements (A–, 

B–). A marker pulse with complement (Z, Z–) is also provided. 

Output resolution on the XR56 is determined by the sensor only.  

Unlike older models, any PPRs can be mixed and matched. Selection of 

the rotor is based only on the shaft mounting requirements (and not PPR).

ADAPTIVE ELECTRONICS

A perfect duty cycle consists of a waveform whose “high” and “low” 

conditions are of the same duration (50%/50%). It is possible over time 

for the duty cycle and edge separation to change due to component drift, 

temperature changes, or mechanical wear. The Adaptive Electronics 

extend the life of the XR56 by constantly monitoring and correcting duty 

cycle and edge separation over time.

INSTALLATION 

 

 WARNING

 

Installation should be performed only by qualified  

 

personnel. Safety precautions must be taken to ensure  

 

machinery cannot rotate and all sources of power are  

 

removed during installation. 

 

Refer to the following attached installation drawings for installation 

information appropriate for specific hazardous locations:

D53008: ATEX / IECEx Zone 1, 21

D52353: ATEX / IECEx Zone 2, 22

D52354: US and Canada Class I Division 1 Encoder

D52355: US and Canada Class I Division 2

 

 

NOTE

 

The equipment is intended for a fixed installation and 

 

should be mounted so as to avoid electrostatic charging. 

 

The XR56 is not considered as a safety device and is not 

 

suitable for connection into a safety system.

The XR56 construction materials contain no more than 7.5% in total by 

mass of magnesium, titanium and zirconium. These materials are not 

considered as able to trigger an explosion in normal operating modes. 

These materials are not known to react with any explosive atmospheres 

to which the XR56 may be subject. The construction materials do include 

aluminum. As such care should be taken to avoid the possibility of 

ignition from impact or friction. It is the responsibility of the end user to 

ensure that the XR56 is selected correctly for the potentially explosive 

atmosphere in which the equipment is to be put into service. 

The XR56 installation is similar to AV56. Installation and removal videos 

for the AV56/67/85/115 are available on Avtron’s web site. Refer to the 

back page of these instructions for outline and mounting dimensions. 

The motor must comply with 1998 NEMA MG 1, section 4, for tolerances 

on diameters and runout for shafts and accessory faces. Axial float or 

endplay plus rotor location tolerance must be less than ±0.050”.

EQUIPMENT NEEDED FOR INSTALLATION 

Provided

Optional

Not Provided

•  AV56 Stator/Housing
•  Socket Hd Cap Screw 3/8"-16 x 1.25" (qty 4)
•  AV56 Rotor
•  Socket Set Screw #M4 x 8mm (qty 2) or Pre-Installed Cam Screw
•  Thread locker (Blue)

•  Extended Shaft Cover w/ Screws 6-32 x 0.31" (qty 4) 
•  Lock Washers
•  Thru Shaft Cover w/ V-Ring Seal and Silicone Lubricant 
•  XRB3 Isolator
•  Model XRB3 for Division I, Zone 0, 1, 20 and 21 Applications 

(Sold Separately)

•  Phillips Screwdriver
•  2mm Hex Wrench (T-Handle Style for set screw Rotors)
•  3mm Hex Wrench
•  5/16" Hex Wrench

Summary of Contents for XR56 SMARTSafe

Page 1: ...all sources of power are removed during installation Refer to the following attached installation drawings for installation information appropriate for specific hazardous locations D53008 ATEX IECEx Zone 1 21 D52353 ATEX IECEx Zone 2 22 D52354 US and Canada Class I Division 1 Encoder D52355 US and Canada Class I Division 2 NOTE The equipment is intended for a fixed installation and should be mount...

Page 2: ...tended pie pan cover Cover Style option E Through shaft covers are avail able for other applications Cover Style option T EXTENDED COVER MOUNT Cover Style option E The extended cover mounts to the encoder housing using quantity 4 6 32 x 0 31 screws lock washers and thread locker THRU SHAFT AND FLAT COVER INSTALLATION Cover Style option T and F The housing has a machined step in the outboard face t...

Page 3: ...RED on a properly mounted XR56 and the rotor is properly located replace the XR56 An oscilloscope can also be used to verify proper output of the SMARTSafe encoder at the encoder connector itself and at the drive controller cabinet If the outputs show large variations in the signals at steady speed jitter or accordion effect see below check rotor position If the rotor position is correct the motor...

Page 4: ...25 MV 70mm T7 3 188 MW 75mm MY 80mm MZ 85mm E Extended Shaft Cover F Flat Cover T Flat Thru Hole Cover with Shaft Seal See Line Driver Connector Options Chart PAGE 5 See Line Driver Connector Options Chart 000 No Modification 005 Super Magnetic Shielding 4xx Special PPR Code consult factory 9xx Special Cable Length xx length in feet 018 Includes Isolator Set Screw Rotor Only 0 Non std F 60 G 100 H...

Page 5: ...n MS W Plug A quad B Std Phasing F 7 Pin MS W Plug A A Std Phasing J 7 Pin MS W Plug A B Z Std Phasing K 7 Pin MS W Plug A A B B Std Phasing S 7 Pin MS W Plug A quad B Dyn Phasing T 7 Pin MS W Plug A A Dyn Phasing U 7 Pin MS W Plug A B Z Dyn Phasing V 7 Pin MS W Plug A A B B Dyn Phasing P Small Industrial Style Std Pinout Plug G Small Industrial Style Northstar Pinout Plug R 10 Pin mini Twist Lock...

Page 6: ...3 lbs 0 9kg to 1 36kg E Sensor to Rotor Air Gap nominal 0 023 0 58mm Tolerance 0 015 0 38mm F Rotor Axial Tolerance 0 050 1 27mm ENVIRONMENTAL Solid cast aluminum stator and rotor Less than 7 5 in total magnesium titanium and zirconium Fully potted electronics protected against oil and water spray Operating Temperature 40 to 80 C 0 100 condensing humidity See Description section for information on...

Page 7: ...T A36521 TT A36523 TT 1 625 1 6245 CJ AVTR1 CJ AVTR2 TJ A36521 TJ A36523 TJ 1 750 1 7495 CK AVTR1 CK AVTR2 TK A36521 TK A36523 TK 1 875 1 8745 CL AVTR1 CL AVTR2 TL A36521 TL A36523 TL 2 000 1 9995 CM AVTR1 CM AVTR2 TM A36521 TM A36523 TM 2 125 2 1245 CN AVTR1 CN AVTR2 TN A36521 TN A36523 TN 2 250 2 2495 CQ AVTR1 CQ AVTR2 TQ A36521 TQ A36523 TQ 2 375 2 3745 CP AVTR1 CP AVTR2 TP A36521 TP A36523 TP ...

Page 8: ...36524 M4 19mm DE AVTR1 DE N A A36522 ME A36524 ME 24mm DF AVTR1 DF N A A36522 MF A36524 MF 28mm DG AVTR1 DG N A A36522 MG A36524 MG 30mm DH AVTR1 DH N A A36522 MH A36524 MH 32mm DT AVTR1 DT N A A36522 MT A36524 MT 36mm DJ AVTR1 DJ N A A36522 MJ A36524 MJ 38mm DK AVTR1 DK N A A36522 MK A36524 MK 42mm DL AVTR1 DL N A A36522 ML A36524 ML 45mm DM AVTR1 DM N A A36522 MM A36524 MM 48mm DN AVTR1 DN N A A...

Page 9: ...30 0 75 MAX x 45 CHF B A 0 002 0 05 0 004 0 10 B A 4 3 8 16 x 1 25 TIGHTENING TORQUE 20 30ft lbs 27 40 NM 2 M4 x 0 7 x 6 0 LG SET SCREW TIGHTENING TORQUE 2 NM ROTOR SETTING TOOL SUPPLIED COVER RETAINER 45 4 500 114 3 DIA 0 66 MIN 16 76 0 72 MAX 18 29 for F flat cover 2 55 MAX 64 8mm for E cover SEE SPARE PARTS CHART FOR AVAILABLE SHAFT SIZES 0 160 4 1 MAX 0 658 0 050 16 71 1 27 0 440 0 005 11 20 0...

Page 10: ...de Phasing Signal 0V Gnd A B Z Vin A B Z K 7 Pin MS Avtron BEI Pinout A A B B CW Pin F A B NC D C E NC F 7 Pin MS Avtron BEI Pinout A A CW Pin F A NC NC D C NC NC J 7 Pin MS Avtron BEI Pinout A B Z CW Pin F A B C D NC NC NC E 7 Pin MS Avtron BEI Pinout A B CW Pin F A B NC D NC NC NC V 7 Pin MS Dynapar Pinout A A B B CCW Pin F A B NC D C E NC T 7 Pin MS Dynapar HS35 Pinout A A CCW Pin F A NC NC D C...

Page 11: ...NE II encoders provide an alarm signal if maintenance is required under specific circumstances An alarm LED indicator is also available Green indicates power on red indicates alarm on Following are application examples provided to help install the alarm output Example 1 Alarm output using V OUT V OUT is equal to V the encoder power supply Example 2 Alarm output using seperate VDC power supply and ...

Page 12: ... 0 265 0 005 6 73 0 13 OPTIONAL ISOLATED DUAL OUTPUT 1 2 14 NPT OPTION P G PLUG IN INDUSTRIAL CONNECTOR ADDITIONAL OPTIONS SHOWN 0 410 10 41 DIA 4 HOLES EQUALLY SPACED ON A 5 875 149 225 DIA RETAINING RING TANG END 8 04 204 2 4 87 123 8 7 53 191 3 5 50 139 7 45 2 75 69 85 STANDARD FLAT COVER 36 00 914 4 MIN OPTION W SEALED FLEXIBLE CABLE 1 09 27 6 2 87 72 9 OPTION R MINI MS WITH PLUG 3 DIMENSIONS ...

Page 13: ...XR56 13 ...

Page 14: ...XR56 14 ...

Page 15: ...XR56 15 ...

Page 16: ...E ARE BASED ON TYPICAL APPLICATIONS CABLE MUST BE SELECTED AND INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND CANADIAN ELECTRICAL CODE PHYSICAL PROPERTIES OF CABLE SUCH AS ABRASION TEMPERATURE TENSILE STRENGTH SOLVENTS ECT ARE DICTATED BY SPECIFIC APPLICATION GENERAL ELECTRICAL REQUIREMENTS ARE STRANDED COPPER 18 THROUGH 14 AWG TWISTED WIRE PAIRS BRAID OR FOIL SHIELDS WITH DRAIN WIR...

Reviews: