Mechanical Installation
Mechanical Installation
31
30
5.6.2 Mounting Steps
The
mounting
steps
in
the
followings
will
take mounting on the
wooden
wall spaced at 32 inch as an example.
NOTE!
Step 1: Fix the bracket
a) Two M4 holes are reserved on the BMS for fixing the bracket of the
inverter.
Ÿ
Screw in M4 screws
to pre-fix t
he
bracket
on
the
BMS
but be sure not to
tighten.
Ÿ
Hold the bracket firmly to the wall surface.
Ÿ
Tighten the M4 screws to fix the bracket on the BMS.
Before mounting the inverter, the mechanical installation of the
whole battery must be completed.
NOTE!
M4
4.4 lbf.in /
0.5 N·m
b) Use the bracket as the template to mark the screw hole location on the
wall.
c) Unscrew the two M4 screws to disassemble the bracket. Drill holes with
power drill, and make sure the holes are deep enough (2.1 in. / 55.0 mm) to
support the inverter.
The figure below is only used for showing the depth and location of
holes. Make sure the holes are in the center of each stud and keep
at least 1.5 in. / 38 mm away from the edge of concrete bricks or
studs before marking holes.
NOTE!
Round holes
Depth:
2.1 in. / 55.0 mm
Φ
4
drill
For solid concrete wall, please use
Φ
10
drill.
NOTE!
Содержание EVERVOLT EVHB-I7