12.2.2 Indoor Unit Installation
12.2.2.1 For the right rear piping
12.2.2.2 For the right bottom piping
12.2.2.3 For the embedded piping
(This can be used for left rear piping and bottom
piping also.)
Piping
Intake grille
Shock absorber
Piping
pull
out
the
pip
in
g
pull
out
the
pip
in
g
• Do not turn over the unit without it’s shock absorber during pull out the piping.
It may cause intake grille damage.
• Use shock absorber during pull out the piping to protect the intake grille from damage.
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Step-1
Secure the Indoor Unit
Insert the connection cable
Step-3
Step-4
Install the Indoor Unit
Pull out the Indoor piping
Step-2
Step-1
Insert the connection cable
Secure the Indoor Unit
Step-3
Step-4
• Use a spring bender or equivalent to bend the piping so that
the piping is not crushed.
• When determining the dimensions of the piping, slide the unit
all the way to the left on the installation plate.
• Refer to the section “Cutting and flaring the piping”.
Bend the embedded piping
Replace the drain hose
• The inside and outside connection cable can be connected
without removing the front grille.
• Please refer to “Connecting the piping” column in outdoor unit
section. (Below steps are done after connecting the outdoor
piping and gas-leakage confirmation.)
Connect the piping
• Please refer to “Insulation of piping connection” column as
mentioned in indoor/outdoor unit installation.
Install the Indoor Unit
Secure the Indoor Unit
Insulate and finish the piping
Step-1
Pull the connection cable into Indoor Unit
Step-3
Cut and flare the embedded piping
Step-4
Step-2
Step-5
Step-6
Step-7
Step-8
Install the indoor unit
Right Rear piping
Hook the indoor unit onto the upper portion
of installation plate. (Engage the indoor unit
with the upper edge of the installation plate).
Ensure the hooks are properly seated on
the installation plate by moving it in left and
right.
Press the lower left and right side of the
unit against the installation plate until hooks
engages with their slot (sound click).
Cover for piping
In case the cover is cut, keep the cover at the rear
of chassis as shown in the illustration for future
reinstallation.
(Left and 2 bottom covers for piping.)
How to keep the c over
Right Bottom piping
Insert the connection cable
Secure the Indoor Unit
To take out the unit, push the marking
at the bottom unit, and pull it slightly towards
you to disengage the hooks from the unit.
Guide
sur face
Connection cable
Connection
cable
Gas side
piping
Liquid side
piping
Drain hose
Ab
ou
t
2
3
/
4
" -
3
5
/
32
"
(70
-80
mm)
Cover for the
bottom piping
Cover for the
bottom piping
Tape it with piping in a
position as mentioned in
Fig. below.
Piping
Drain
hose
Cover for
the left
piping
Cover for
the bottom
piping
Tape it with piping in a
position as mentioned in
Fig. below.
Piping
Drain hose
Cover for
the left
piping
Drain hose
Sleeve for
piping hole
Indoor unit
Hooks at
installation
plate
Piping
Installation
plate
Unit’s hook
marking