147
18.1.10 CS-XE24WKUAW CU-XE24WKUA
Maximum Capacity
Indoor (°C / °F)
Outdoor (°C / °F)
DB
WB
-20 (-4.0)
-10 (14.0)
0 (32.0)
5 (41.0)
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
27
(80.6)
19 (66.2) 33661
27566
1813
33627
27538
1791
33585
28033
1738
33492
27412
1722
22 (71.6) 38613
22532
1584
38574
22510
1565
36771
22020
1815
34298
20646
1810
23
(73.4)
16 (60.8) 29622
29326
2000
29593
29297
1976
31460
31145
1645
29992
29692
1824
18 (64.4) 33117
21207
1831
33084
21186
1809
36862
22845
1432
34344
21182
1904
20
(68.0)
13 (55.4) 26077
25816
1985
26050
25790
1960
25882
25623
1302
24947
24698
1556
16 (60.8) 26009
18694
2291
25983
18676
2263
27228
19305
1354
29433
20613
1336
Indoor (°C / °F)
Outdoor (°C / °F)
DB
WB
16 (60.8)
25 (77.0)
35 (95.0)
46 (114.8)
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
27
(80.6)
19 (66.2) 33362
27770
1699
29194
24691
2316
27320
24588
2520
18752
16877
2266
22 (71.6) 34514
21187
1704
31746
19541
2341
30147
15360
2553
20693
10543
2295
23
(73.4)
16 (60.8) 30935
30625
1699
27010
26740
2272
25001
24751
2661
17160
16989
2392
18 (64.4) 33763
21102
1703
29691
18807
2296
27523
18240
2709
18891
12520
2436
20
(68.0)
13 (55.4) 27043
26773
1422
25298
25045
2270
23053
22823
2614
15824
15665
2350
16 (60.8) 30784
20001
2304
30316
20463
2914
25751
10132
2848
17675
6954
2560
TC - Total Cooling Capacity (BTU)
SHC - Sensible Heat Capacity (BTU)
IP - Input Power (W)
Содержание CS-XE9WKUAW
Страница 45: ...45 10 1 5 Nanoe X Printed Circuit Board...
Страница 122: ...122 17 1 1 5 To Remove Cross Flow Fan and Indoor Fan Motor Figure 9 Figure 10 Figure 11...
Страница 123: ...123 Figure 12...