70
13.4.2 Horizontal
Airflow
Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Operation Mode
Vane Angle (°)
Heating, with heat exchanger temperature
A 65
~115
B 90
Cooling and soft dry
65 ~115
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Pattern
1 2 3 4 5
Airflow Direction Patterns at
Remote Control
Vane Angle (°)
90
65
77.5
102.5
115
13.5 Quiet operation (Cooling Mode/Cooling area of Dry Mode)
Purpose
o
To provide quiet cooling operation condition.
Control
condition
o
Quiet operation start condition
When FAN SPEED/QUIET button at remote control is pressed continuously until QUIET will be shown on
remote control display.
o
Quiet operation stop condition
POWERFUL button is pressed.
Stop by OFF/ON switch.
Timer OFF activates.
When FAN SPEED/QUIET button is pressed again.
Control
contents
o
Fan speed is changed to QLo.
o
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
o
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
o
After off, when on back, quiet operation is memorized.
13.6 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to 3.6°F (2°C) (for
Cooling/Soft Dry) or higher up to 6.3°F (3.5°C) (for Heating) than remote control setting temperature for
20 minutes to achieve the setting temperature quickly.
13.7 Timer Control
There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
109.4°F (43°C)
104°F (40°C)
0°
Top View
2
3
1
4
5
B: fix front
A: swing
Indoor Heat Exchanger
Temperature
Figure 1
Figure 2