How to Fix Installation Plate

To Drill a Hole in the wall and install a sleeve of piping

Installation instructions

Indoor Unit

The mounting wall shall be strong and solid enough to prevent it from vibration.

Model

Dimension

KU12 Series, SU12 Series, NU12 Series,

SU18_T Series, YU12 Series

 

NU18 Series, KU18 Series, KZ18 Series,

TU18 Series, KU24 Series, SU24 Series, 

NU24 Series, KZ24 Series, YU18 Series,

YU24 Series

490 mm

590 mm

82 mm

82 mm

439 mm

539 mm

432 mm

532 mm

43 mm

169 mm

95 mm

219 mm

3

4

5

6

Wall

Wall

Wall

Installation plate 

 screw

More than 

More than 

Indoor unit

241.5 mm

128 mm

241.5 mm

128 mm

128 mm

More than 

For best strength of INDOOR 

unit installation, it is highly 

recommended to locate “ ” 

at 5 position as shown.

Measuring 

Tape

 

The center of installation plate should be at more than       at right and left of the wall.

The distance from installation plate edge to ceiling should more than      .

From installation plate center to unit’s left side is      .

From installation plate center to unit’s right side is      .

        :   For left side piping, piping connection for liquid should be about       from this line.

        :   For left side piping, piping connection for gas should be about       from this line.

        1   Mount the installation plate on the wall with 5 screws or more (at least 5 screws).

             (If mounting the unit on the concrete wall, consider using anchor bolts).

              •   Always mount the installation plate horizontally by aligning the marking-off line with the thread and using

 

 a level gauge. 

        2   Drill the piping plate hole with ø70 mm hole-core drill.

              •   Line according to the left and right side of the installation plate. The meeting point of the extended line is 

 

 the center of the hole. Another method is by putting measuring tape at position as shown in the diagram 

 

 above.

 

 The hole center is obtained by measuring the distance namely 150 mm (1.0~1.5HP) for left and right hole

 

 respectively or 210 mm for left hole and 150 mm for right hole (2.0~2.5HP).

              •  Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.

B  

 

1  Insert the piping sleeve to the hole.

2  Fix the bushing to the sleeve.

3  Cut the sleeve until it extrudes 

    about 15 mm from the wall.

4  Finish by sealing the sleeve with putty 

    or caulking compound at the final stage.      

15 mm

Putty or caulking 

compound

ø70 mm 

through 

hole

Indoor

Outdoor

Sleeve 

for tube 

assembly

Approx. 

5 - 7 mm

Bushing 

for tube 

assembly

Wall

CAUTION

           

When the wall is hollow, please be 

sure to use the sleeve for tube 

assembly to prevent dangers caused

by mice biting the connection cable.

Содержание CS/CU-KU12ZKY Series

Страница 1: ...n the installer should Read the Installation Operating Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit Air conditioner Opera...

Страница 2: ...and COOL mode 16 C 30 C Operating the unit within the recommended temperature range may save energy HEAT 20 C 24 C COOL 26 C 28 C Default set temperature is 24 C in COOL mode as per country guidelines...

Страница 3: ...E POWERFUL AIR SWING FAN SPEED SLEEP TEMP CLEAN TIMER ON OFF CLOCK LOCK CANCEL ECO converti7 SMART AIR CONDITIONER FAN CHECK MODE POWERFUL AIR SWING FAN SPEED SLEEP TEMP CLEAN TIMER ON OFF CLOCK LOCK...

Страница 4: ...of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock o...

Страница 5: ...e the same as conventional refrigerant R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Espec...

Страница 6: ...accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as...

Страница 7: ...where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being co...

Страница 8: ...nd during the brazing process 8 Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important...

Страница 9: ...hat it has been de commissioned and emptied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Rec...

Страница 10: ...er every 3 hours operation Press hold for 5 seconds to turn ON OFF the hidden display Press for 5 seconds to lock unlock remote keypad When keypad is locked remote display will show LO when any button...

Страница 11: ...in to increase timer time in step of 10 minutes or CL will be displayed on unit and remote controller CL on unit display is not applicable for LU Models While CL is displayed all other functions of th...

Страница 12: ...be upto 70 Step 6 55 is display on Unit and Remote Unit Input Power will be upto 55 Step 7 40 is display on Unit and Remote Unit Input Power will be upto 40 Press converti7 button again to exit from...

Страница 13: ...the filter surface Dry the dust filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM0 1 filter Clean the filter whenever necessary Don t was...

Страница 14: ...some alpha numeric codes appear on IDU display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED continu...

Страница 15: ...15 Troubleshooting Notes...

Страница 16: ...ted There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles whic...

Страница 17: ...as leaks and secure with vinyl tape Vinyl tape Insulation of piping connections Remote control holder Remote control holder xing screws Remote control Attaching the remote control holder to the wall 5...

Страница 18: ...this line 1 Mount the installation plate on the wall with 5 screws or more at least 5 screws If mounting the unit on the concrete wall consider using anchor bolts Always mount the installation plate...

Страница 19: ...left piping Right Rear piping Cover for piping How to keep the cover In case of the cover is cut keep the cover at the rear of chassis as shown in the illustration for future reinstallation Left right...

Страница 20: ...m m Connection cable Gas side piping Liquid side piping Drain hose Insert the connection cable This can be used for left rear piping and bottom piping also How to pull the piping and drain hose out i...

Страница 21: ...roprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Bind all the indoor and outdoor connection cable with t...

Страница 22: ...n this area must follow to national wiring rules Do not joint wires Wire stripping No loose strand when inserted 10 1 mm Conductor fully inserted ACCEPT Conductor over inserted PROHIBITED Conductor no...

Страница 23: ...e speci ed torque as stated in the table Do not overtighten overtightening may cause gas leakage Piping size Torque 6 35 mm 1 4 18 N m 1 8 kgf m 9 52 mm 3 8 42 N m 4 3 kgf m 12 7 mm 1 2 55 N m 5 6 kgf...

Страница 24: ...unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1 0 mm2 1 5 1 8HP 4 x 1 5 mm2 2 0HP or 4 x 2 5mm2 2 5HP exible cord type designation IS 694 or 60245 IEC 57 or heavier cord Do not...

Страница 25: ...aps 1 5 2 0HP or 3 caps 2 0 2 5HP on the front grille as shown in the illustration at top and then remove the 4 mounting screws 3 Pull the lower section of the front grille towards you to remove the f...

Страница 26: ...insulating material with a new one Heat insulating material is required for both liquid side and gas side piping Most Important Process Purpose To make the oil refrigerant mix together They are in se...

Страница 27: ...oint connection of indoor unit by aring method can only be made at outdoor or at outside of a buidling or dwelling or room Flare connection may cause gas leak and ammable atmospheres For R32 R410A mod...

Страница 28: ...e for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 C for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 C for Half Load 50 For Full Load For...

Страница 29: ...top For COOL Mode This test guideline is applicable for KZ models only FULL LOAD HALF LOAD FULL LOAD HALF LOAD QUIET CLEAN Open the Front Panel by lifting Intake Grille Follow the below Instructions 4...

Страница 30: ...ranty for 3 years from the date of purchase Product ROOM AIR CONDITIONER Panasonic Life Solutions India Pvt Ltd Model No ODU SI No IDU SI No Customer Name Address Tel No Date of Purchase Invoice No De...

Страница 31: ...re eg Rat lizard insect ants etc inside the Product unit f Use of harmful chemicals Improper heat load Usage of unit in an abnormally corrosive alkaline acidic atmosphere g Any change or defect result...

Страница 32: ...m in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should b...

Отзывы: