14.
DC IN connector <12V IN
>
Connect the AC adaptor supplied with the unit to this connector to
supply the DC 12 V voltage to the unit.
AC adaptor
Be sure to use the supplied AC adaptor.
15.
Cable clamp
This is used to hold the cable connection to the DC IN connector and
prevent it from becoming disconnected.
16.
IR ID switches <IR ID>
CAM1
CAM2
CAM3
CAM4
These are used to select the ID of the wireless remote control
(optional accessory). (→ page 30)
The IR ID switch settings “CAM1” to “CAM4” correspond to the
<CAM1> to <CAM4> buttons on the wireless remote control.
17.
3G SDI OUT connector <3G SDI OUT>
This is an SDI video signal output connector. Depending upon the
output signal format, 3G-SDI or 1.5G-SDI signals are output.
18.
12G SDI OUT connector <12G SDI OUT>
This is an SDI video signal output connector. Depending upon the
output signal format, 12G-SDI, 6G-SDI, 3G-SDI or 1.5G-SDI signals
are output.
19.
HDMI connector <HDMI>
This is the HDMI video output connector.
20.
Ground connector
Connects to the ground connector on a wall outlet, ground bar, etc.
for grounding. (→ page 8)
21.
Service switches <SERVICE>
Perform switch settings before turning the unit on.
DC IN 12 V
IR ID
AUDIO IN
RS-422
SERVICE
12G SDI OUT
3G SDI OUT
G/L IN
LAN
LINK ACT
Service switches
Function
Factory settings
SW1
Switches for initialization
(Refer to the explanations in “Initialization 1”
and “Initialization 2”)
OFF
SW2
Always leave at OFF (used for factory
adjustments)
OFF
SW3
OFF
SW4
OFF
Initialization 1
• Reset the user authentication settings and host authentication
settings for network connection.
(This will delete all the registered user information (IDs/passwords)
and host information (IP addresses).)
• With the IR ID switches and service switches set as shown below,
turn on the power of the unit.
SW1
ON
OFF
SW2 SW3 SW4
<NOTE>
• When initialization is complete, the status display lamp on the
front of the unit blinks green. Set the service switches back to their
original positions (SW1 to SW4 all OFF), then restart the unit.
Initialization 2
• The unit is reset to the state it was in at the time of purchase. (All
camera menu setting values and network setting values are reset.)
• With the IR ID switches and service switches set as shown below,
turn on the power of the unit.
SW1
ON
OFF
SW2 SW3 SW4
<NOTE>
• When initialization is complete, the status display lamp on the
front of the unit blinks green. Set the service switches back to their
original positions (SW1 to SW4 all OFF), then restart the unit.
22.
Tripod screw holes
(Screw: 1/4-20 UNC, ISO 1222 [6.35 mm (1/4 inches)])
Use these screw holes when securing the unit to a tripod, etc.
18
19
Parts and their functions (continued)