35
3. Basic operations
Turn [F4] to select the button to which the SHIFT function is to be allocated using the Shift item.
Right:
Button No.16
Left:
Button
No.1
Off:
Function is not allocated.
Turn [F5] to select the operation to be performed when the [SHIFT] button is pressed using the Sf-Lock item.
Off:
The rear material is selected only while the [SHIFT] button is pressed.
On:
The front material and rear material are switched each time the [SHIFT] button is pressed.
To use the materials that have been set in the button to which the SHIFT function is allocated, either set the
SHIFT function off or allocate the SHIFT function to another button.
If a rear material has been selected regardless of whether the Sf-Lock item is On or Off, both the button
concerned and the [SHIFT] button will light in amber.
When PGM/PST is selected as the bus mode setting or when the bus has been switched by a transition, the
SHIFT status will also be switched.
If the [SHIFT] button for “Single SHIFT” is pressed when the rear materials (17 to 32) have been selected
using “All SHIFT”, the bus crosspoint buttons concerned will be switched to the front materials.
When a crosspoint button is held down, the input material allocated to the pressed button is displayed on the
LCD.
When the [SHIFT] button is held down, “Shift” is displayed on the LCD.