104
4. Input/output signal settings
4-1-5.
Setting the up-converter
Select the settings for INPUT13 to 16, as well as for the up-converter that is built into the optional boards listed
below:
AV-HS04M1 (SDI Input Board)
AV-HS04M2 (Analog Input Board)
AV-HS04M6 (Analog Composite Input Board)
Press the [INPUT] button to light its indicator and display the INPUT menu.
Refer to “2-1-5. LCD menu area”.
<Menu
display>
INPUT XX|UpConv1|Scale |MovDet↓|Sharp↓
| 4/13 |
SQ|
3|
3
EC
LB
1~5 1~5
Turn [F1] to display the INPUT XX sub menu.
(X: IN1 to IN16, A1, A2, B1 or B2)
The input used to set the up-converter is selected for X.
Turn [F2] to display the third menu of UpConv1.
Turn [F3] to select the scaling system using the Scale item, and press the [F3] switch to enter the selection.
SQ (squeeze):
The image is enlarged both horizontally and vertically to fill the entire screen.
EC (edge crop):
The aspect ratio of the image is maintained, the image size is increased in accordance
with the vertical resolution, and black bands are added at the left and right.
LB (letter box):
The aspect ratio of the image is maintained, the image size is increased in accordance
with the horizontal resolution, and the image is cropped at the top and bottom.
Input image
SQ
EC
LB
Turn [F4] to set the image movement detection sensitivity using the MovDet item, and press the [F4] switch
to enter the selection.
1:
Toward still images
3:
standard
5:
toward moving images
Turn [F5] to set the extent of the edge sharpness for the images using the Sharp item, and press the [F5]
switch to enter the selection.
1:
Not sharp edges
3:
standard
5:
very sharp edges