126
For Long and Trouble-Free Operation: Warning System
Stor-
age
LACK OF CAPACITY!
Not enough free space left on the storage de-
vice.
Use a new storage device with enough free space or
a formatted storage device.
MISMATCH
COMPONENT!
The model numbers of the copy source P2 card
and copy destination P2 card do not match.
Copying is not possible.
Use P2 cards of the same model number or import
clips individually.
TOO MANY PARTITIONS! There are too many partitions.
The maximum number of partitions for a storage de-
vice is 23. Use a new storage device or reformat the
storage device.
UNKNOWN DEVICE
CONNECTED!
An unsupported DVD drive or other device is
connected.
Connect a supported storage device, and then turn
the power off and then back on.
VERIFICATION FAILED!
Verification after copying failed.
Copy the data again.
Soft-
ware
key-
board
CANNOT CHANGE!
An attempt was made to change PERSON when
no text memo had been entered.
First enter a text memo.
CANNOT SET!
The entered value is invalid.
Enter a valid value.
INVALID VALUE!
AUTHENTICATION
ERROR!
Manual authentication failed.
Enter the correct password.
Net-
work
CANNOT CONNECT!
A connection cannot be established to the net-
work.
Check that the LAN settings are correct, LAN cable is
connected properly, and network is working properly.
CANNOT FIND FTP-
SERVER!
The connection destination FTP server cannot be
found.
Check whether the URL item of FTP CLIENT is cor-
rect.
LOGIN FAILED!
Logging in to the connection destination FTP
server failed.
Check whether the USER ID and USER PASSWORD
items of FTP CLIENT are correct.
PING FAILED!
The ping failed.
Check that the LAN settings and the URL item of FTP
CLIENT are correct, LAN cable is connected proper-
ly, and network is working properly.
CANNOT ACCESS GATE-
WAY!
The gateway server cannot be accessed.
Check that the LAN settings are correct.
CHECK LAN SETTING
The gateway server cannot be accessed.
Check that the LAN settings are correct.
IP ADDRESS IS USED!
The set IP ADDRESS is being used by another
device.
Consult with the network administrator and then set
another IP ADDRESS.
INVALID VALUE!
The entered data is invalid.
Enter data in a valid range.
UPLOAD LIST ERROR!
Addition to the upload list failed.
• Configure “REC DURING UPLOAD” (
➝
page 105)
again.
• Check whether the registration limit (100 entries) for
the upload list has been reached.
Item
Message
Description
Measure