140
Maintenance and Inspections : Maintenance
6. Inspection of the clock, time code, and user bits
1
Set the user’s bit as required.
Please refer to [Setting of the user bits] (page 57) for
the setting procedures.
2
Set the time code.
Please refer to [Setting the Time Code] (page 61) for
the setting procedures.
3
Set the TCG switch to [R-RUN].
4
Press the REC START/STOP button.
Check that the counter display number changes as
recording progresses.
5
Press the REC START/STOP button again.
Check that recording stops and the counter display
number stops changing.
6
Set the TCG switch to [F-RUN].
Check that the counter display number changes
regardless of recording status.
7
Set the DISPLAY switch to [UB].
Each time the HOLD button is pressed, make sure
that the displayed value changes in the following
sequence: VTCG
>
DATE
>
TIME
>
No display
(time zone)
>
TCG; and also verify that the displayed
value is correct.
If DATE, TIME, or time zone is not correct, refer to
[Setting the Internal Clock’s Date and Time] (page 60)
for guidance on setting the correct values.
Note
Note that date and time data set for DATE, TIME, and
time zone is recorded in clips, and affects the
playback sequence, etc. at the time of thumbnail
manipulations.
z
Do not use thinner or other solvents to remove dirt.
z
Wipe the lens with a commercially available lens cleaner.
z
Do not wipe the mirror. If dirt or rubbish is sticking on the mirror, remove it with a commercially available air blower.
Smears
Smears may appear when shooting an object with very
high brightness.
This phenomenon becomes more obvious as the
electronic shutter speed becomes faster.
The camera is shipped from the factory with a backup
battery already mounted.
When the battery runs out, the [BACK UP BATT EMPTY]
display appears on the viewfinder screen for 5 seconds
after the power switch is turned ON.
The internal clock stops operating when the battery runs
out. Also, the TCG time code value returns to
[00:00:00:00], and the time code backup is disabled. The
battery must be replaced.
Please consult your distributor for replacement with a new
battery (CR2032).
The backup battery is visible when the panel on the LCD
monitor side is removed (right side when viewed from the
front).
Maintenance
Cleaning Inside the Viewfinder
Phenomenon Inherent to CCD Cameras
Replacing the Backup Battery
Note
Please contact the store where you purchased the
camera when replacing the battery.
AJ-HPX2000P(VQT1D27-1)E.book 140 ページ 2007年7月30日 月曜日 午後1時31分