130
Service functions
(not available for all models)
Status
Description
Action for disabling
Error
No voltage across J1/2 -> check fuse
Automatic error reset as soon as
voltage is present across J1/2.
Error
Emergency program, sensor system
being bridged. Re-enable by pressing
and holding “Open“ and “Lower“ push-
buttons for more than 10 seconds.
Switch off/on control box
Error
Error diagnosis of all inputs is active.
Warnfix is activated upon each push-
button actuation.
Remove service plug
Error
“Selflock” function is active. Tail lift is
locked via radio receiver
(e. g. ICP).
Selflock = automatic locking of the con-
trol panel when the vehicle is left
Reset “Selflock” function:
Switch off/on control box or
place radio transmitter near the ra-
dio receiver again
Error
Interface not active due to short circuit
of “JP” connector (CAN).
De-energize board for some sec-
onds
Error
Error of special function (e. g. light bar-
rier of vertical lift program V-SYCL) is
defective.
Switch tail lift to emergency opera-
tion / replace light barrier
Bedienung_Tastencode_EN.fm Seite 130 Donnerstag, 15. August 2019 4:13 16
Содержание MBB C 1000 S
Страница 3: ...Betriebsanleitung_Hubladebuehnen_EN book Seite 3 Donnerstag 15 August 2019 4 04 16...
Страница 41: ...41 Betriebsanleitung_Hubladebuehnen_EN book Seite 41 Donnerstag 15 August 2019 4 04 16...
Страница 63: ...63 Betriebsanleitung_Hubladebuehnen_EN book Seite 63 Donnerstag 15 August 2019 4 04 16...
Страница 77: ...77 Betriebsanleitung_Hubladebuehnen_EN book Seite 77 Donnerstag 15 August 2019 4 04 16...
Страница 81: ...81 Betriebsanleitung_Hubladebuehnen_EN book Seite 81 Donnerstag 15 August 2019 4 04 16...
Страница 85: ...85 Betriebsanleitung_Hubladebuehnen_EN book Seite 85 Donnerstag 15 August 2019 4 04 16...
Страница 89: ...89 Betriebsanleitung_Hubladebuehnen_EN book Seite 89 Donnerstag 15 August 2019 4 04 16...