Retract
Fault
Possible cause
Remedy
Platform does not re-
tract, motor is running
Solenoid valves S 7 and S 8
leaking
Clean or replace
Solenoid valve S 7 does not
open
Clean or replace
Solenoid valve S 11 does not
open
Clean or replace
Piston seal in guide cylinder
defective
Replace
Fold in
(for model MBB R 1500 SH – R 2000 LH)
Fault
Possible cause
Remedy
Platform does not un-
fold, motor is running
Solenoid valves S 7 and S 8
leaking
Clean or replace
Solenoid valve S 12 does not
open
Clean or replace
Solenoid valve S 9 does not
open
Clean or replace
Piston seal in folding cylinder
defective
Replace
Switch on warning light
(warning light is automatically switched on when the platform is opened or extended,
left and right lights are switched in parallel)
Fault
Possible cause
Remedy
Warning lamps are nor
flashing
Short-circuit in lamp or ca-
bling
Repair short-circuit
Lamp defective
Replace
Initiator b25 defective
Replace
Betriebsanleitung_Hubladebuehnen_EN.book Seite 159 Donnerstag, 15. August 2019 4:04 16
Содержание MBB C 1000 S
Страница 3: ...Betriebsanleitung_Hubladebuehnen_EN book Seite 3 Donnerstag 15 August 2019 4 04 16...
Страница 41: ...41 Betriebsanleitung_Hubladebuehnen_EN book Seite 41 Donnerstag 15 August 2019 4 04 16...
Страница 63: ...63 Betriebsanleitung_Hubladebuehnen_EN book Seite 63 Donnerstag 15 August 2019 4 04 16...
Страница 77: ...77 Betriebsanleitung_Hubladebuehnen_EN book Seite 77 Donnerstag 15 August 2019 4 04 16...
Страница 81: ...81 Betriebsanleitung_Hubladebuehnen_EN book Seite 81 Donnerstag 15 August 2019 4 04 16...
Страница 85: ...85 Betriebsanleitung_Hubladebuehnen_EN book Seite 85 Donnerstag 15 August 2019 4 04 16...
Страница 89: ...89 Betriebsanleitung_Hubladebuehnen_EN book Seite 89 Donnerstag 15 August 2019 4 04 16...