USE AND MAINTENANCE
9.4
HOW TO USE THE DOOR
The opening of the door is obtained by grasping the
handle and pushing it up (Fig. 9.2).
'XULQJRSHUDWLRQRIWKH¿UHSODFHLWLVUHTXLUHGWRNHHSWKH
door completely lowered.
Fuel loading is to be carried out with the door completely
open because any other intermediate positions may
cause smoke to come out, or it may provoke a forge
effect with violent combustion resulting in higher wood
consumption. In case of abnormal functioning of the door,
check the lifting mechanisms, accessing them through
the inspection panel.
The sliding and lifting
system of the door is handled
by special sleeves that guarantee minimum fricition and
maximum silence. Once a year, make sure the system
LVZRUNLQJHI¿FLHQWO\
When the fire is lit, the door reaches very high
temperatures.
The door can be opened by swinging it out to clean the
glass.
:KHQORDGLQJZRRGLQWRWKH¿UHER[GRRURSHQLQJWDNHV
place in two steps
¿UVWVORZO\DQGSDUWLDOO\FPWRDOORZVPRNHIURP
WKH¿UHER[WREHDVSLUDWHGE\WKHÀXH
then completely, thus preventing smoke form coming
out into the room.
Check for any “speci
¿
c features of the model” in the
enclosed “product booklet”.
9.5
SMOKE VALVE (VDF
®
)
Ecomonoblocco models are equipped with the new
control for the regualtion of the quantity of combustion
smoke outlet.
This adjustment makes it possible to control combustion
by adjusting the draught based on installation conditions
or atmospheric conditions.
The control also allows automatic opening of the smoke
YDOYH ZKHQ WKH ¿UH ER[ GRRU LV OLIWHG WKXV SUHYHQWLQJ
smoke form entering the room.
1RUPDOO\WKLVDGMXVWPHQWLV¿[HGDQGLVSHUIRUPHGZKHQ
LQVWDOOLQJWKH¿UHSODFH
Do not adjust the valve continuously. This does not
control combustion.
9.6
OPERATION
The
adjustment device
lets you vary the position of
the smoke valve from “fully closed” to “fully open” in
an extremely gradual manner, thanks to the innovative
micrometric selector.
To adjust the opening of the smoke valve turn the
knurled knob to the left (closure) or to the right
(opening). It will be possible to view the degree of
opening on the graduated scale located to the left of
the control
¿J
:KDWHYHUDGMXVWPHQWLVFKRVHQZKHQWKHGRRURIWKH¿UH
box is lifted, the mechanism will automatically place the
smoke valve in the “fully open” position, thus preventing
smoke from getting into the room. When the door is
closed again, the valve will again automatically return to
the previously set position.
Check for any “speci
¿
c features of the model” in the
enclosed “product booklet”.
A- display of valve opening;
B- opening of valve in relation to the direction of rotation
of the selector).