![Palazzetti Ecomonoblocco Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/palazzetti/ecomonoblocco/ecomonoblocco_instructions-for-use-and-maintenance-manual_3302915039.webp)
- 7.1 -
INSTALLATION
ENGLISH
7 OPTIONAL
7.1 KIT
SCINTILLA
®
(ONLY FOR CERTAIN
MODELS)
Scintilla
®
is a device that allows automatic ignition of
WKH¿UHSODFHVLQWKH(FRPRQREORFFRVHULHV,JQLWLRQPD\
take place by means of a switch which may or may not
be timer-controlled, or by GSM with an optional actuator.
7.2
O
2
RING
®
O
2
Ring is the revolutionary system for reducing harmful
emissions produced by combustion gases.
Installing the O
2
Ring kit before the chimney connection
reduces harmful emissions by up to 80%.
7.3
COMBUSTION AIR INTAKE
This component, installed underneath the Ecomonoblocco,
is used to carry combustion air from the outside through
VXLWDEOHGXFWZRUNGLUHFWO\LQWRWKH¿UHSODFH7KLVDYRLGV
taking in cold outside air into the room.
7.4
FAN WITH EXTERNAL CONTROL UNIT
The kit is composed of the control unit, and electric fan
and a minimum temperature thermostat or probe. The
control unit is used to switch the fan on and off, manually
or automatically, as well as to control motor speed
manually, automatically or proportionally.
,Q(FRPRQREORFFRYHUVLRQVZLWKORZ¿UHEHGNLWWKHIDQNLW
also includes the extension feet for installation of the fan.
In 16:9 3D model,
before mounting the fan kit make sure
to turn up the supporting feet of the stove
at least 5 cm
from the minimum size.
7.4.1 ELECTRIC FAN CONNECTION (OPTIONAL)
In addition to the combustion air intake
C
it is also
necessary to provide air intakes for the fan.
A
Room air intake to heating circuit fan, located
laterally to the cladding (diameter 14 cm) with grille
measuring
15x25.
B
Ambient air intake connected to an adjacent room
(except kitchen, bathroom, sleeping room), dimensions
FP
[¿J
Connect the air convection fan (
V
) to the inlet pipes
EHORZWKH¿UHER[
.
On Ecomonoblocco models with smaller feet, this solution
is only possible by installing the extension leg kit.
Is forbidden to avoid leaving the fan disconnected
IURP WKH DVSLUDWLRQ SLSHV XQGHU WKH ¿UH EHG LW PD\
GUDZ LQ VPRNH IURP WKH ¿UH ER[ DQG SODFH LW LQ WKH
heating circuit.
For further details, see the instructions included in the
fan kit.
If installation is performed as shown in Figure 5.8b, make
sure there is a distance of at least 50 cm between the
combustion air intake and the fan intake.
cod. 004771651 MBL - 06/2015 - Palazzetti - PN - Italy
39