A
B
- 5.1 -
INSTALLATION
5 PREPARING
THE PLACE OF
INSTALLATION
5.1 SAFETY
PRECAUTIONS
The user is responsible for the work carried out in the
DUHDZKHUHWKH¿UHSODFHLVLQVWDOOHGWKHXVHULVOLNHZLVH
responsible for checking the various installation solutions
proposed.
The user must comply with all the local, national and
European rules and regulations.
If the floor does not have a sufficient load-bearing
capacity, it is advisable to use a load-distributing plate
of an appropriate size.
The appliance must be installed on a floor with an
adequate carrying capacity
The stove assembly and disassembly operations must
be carried out by skilled technicians only.
7KHTXDOL¿FDWLRQVDQGHIIHFWLYHH[SHUWLVHRIVXFKVNLOOHG
WHFKQLFLDQVVKRXOGEHYHUL¿HG
Before starting the assembly or dismantling phases of
the machine, the installer must comply with the safety
precautions as established by law, and in particular as
regards
A) he must not work in adverse conditions;
B) he must be in perfect psychophysical condition to
work and ensure that the individual and personal
accident prevention devices are sound and in perfect
working order;
C) he must wear accident prevention gloves;
D) he must wear safety shoes;
E) he must make sure that the area he is working in
IRU DVVHPEOLQJGLVPDQWOLQJ WKH VWRYH LV IUHH IURP
obstacles.
5.2 DRY
POSITIONING
,WLVDGYLVDEOHWRSUHDVVHPEOHWKH¿UHSODFHGU\VRDV
to understand how much space the various components
and air intake passageways take up.
It is necessary to match the front part of the unit with
the inside edge of the marble slab, leaving a 5 mm slot
so as to allow for free dilation of the Ecomonoblocco.
)RUWKHPRGHOVZLWKWKHKHLJKWRIWKH¿UHSODQORZHUWKDQ
PP
UHPRYHWKHIUHVKDLUSOHQXP
A
)
SODFH WKH LQVXODWLRQ SODWH
B
RQ WKH ÀRRU EHORZ WKH
EMBL (Fig. 5.1)
Palazzetti claddings are realized in compliance safety
and technical requirements as set forth by current
standards.
5.2.1
Safety recommendations
The cladding of the fireplace, regardless of the
material used, must be self-bearing with respect to the
Ecomonoblocco and it must not be in contact with it.
Any wood beams, or any finishing in combustible
material, must be suitably insulated (or placed outside
WKHDUHDRIUDGLDWLRQRIWKH¿UHSODFHDQGPXVWEHDWD
GLVWDQFHIRUPWKH(FRPRQREORFFRRIDWOHDVWFP¿J
WRJXDUDQWHHIUHHDLUÀRZWRDYRLGRYHUKHDWLQJ
Any coverings in combustible material located over
the generator must be shielded by diaphragms in non-
combustible insulating material.
,QSUHVHQFHRIÀRRUVPDGHRIFRPEXVWLEOHPDWHULDOPXVW
EHSODFHGEHWZHHQWKH¿UHSODFHDQGWKHÀRRUD¿UHSURRI
panel (already included on some models).
32